HYDRAFORCE LIFT STATION AGITATOR MANUAL
6
Suggested Tools & Supplies
• Phillips-head screwdriver
• Flat-head screwdriver
• 5/16” socket or nut driver
• 1/4” socket or nut driver
• 9/32” socket or nut driver
• 3/8” socket or nut driver (#10 nuts)
• 7/16” socket or nut driver (1/4” nuts)
•
Thread sealant (Teflon tape)
NO-CABINET INSTALLATION
Installation Conditions & Clearances
• Install compressor in a clean, dry location.
• Protect the compressor from dirt, moisture, and any harmful elements of the outdoor environment.
• Ambient air temperature must not exceed 104 °F (40 °C).
•
Adequate ventilation and cooling air (airflow across the compressor) is essential to prevent damage to
the compressor from overheating. A fan is included for this purpose.
•
Easily mount the unit to a wall, floor, or bench with the included bracket.
•
Packages containing 120V compressors have a NEMA 5-15 plug.
For your protection, Kasco recommends that the site service providing system power is equipped with a
human-rated ground fault circuit interrupter outlet (120V). Contact a licensed electrician to install either
120V single-phase power at the compressor location with appropriate human-rated ground fault protection.
Brown
Black
Blue
White
Green w/ stripe
Green
Wiring Connections
Electrical wiring color codes may vary by country/region.
Check local codes before making connections.
Back to Contents