background image

3400 - 4400 J SERIES FOUNTAIN MANUAL

8

Proper Installation 

Proper installation of Kasco equipment will include a power source with ground fault protection. The 

control panel included with the equipment has built-in ground fault protection. Ground fault interrupters 

can also alert you to electrical leaks in the equipment. It is extremely important to test the GFCI upon 

installation and every month thereafter to ensure proper operation. In the case of consistent trips of 

the ground fault device, disconnect the equipment and remove it from the water. Inspect the power 

cord for damage and contact your distributor or Kasco Marine (715.262.4488, [email protected]

for further instructions. A complete list of control panels can be found in the Accessories section of 

kascomarine.com.

ALWAYS DISCONNECT POWER BEFORE PERFORMING MAINTENANCE. 

Observation  

Observe equipment in operation on a regular basis (daily, if possible). If you observe a change in 

performance, disconnect the equipment from the power source and inspect for any material clogging 

the system or wrapped around the motor shaft. To avoid damage to the equipment, it is important to 

remove clogs as soon as possible. ALWAYS DISCONNECT POWER TO THE UNIT BEFORE ATTEMPTING TO 

REMOVE CLOGS.  

Cleaning 

Buildup of algae, calcium, barnacles, or other matter on the motor housing creates insulation and blocks 

heat transfer, so to prevent overheating, it is important to clean the unit. In warmer regions or in other 

areas prone to buildup such as this, inspect and clean the equipment regularly. In all regions, inspect and 

clean the equipment at least once a year. It is easiest to clean the unit immediately after removing it from 

the water, when the equipment is still wet. If you use a power washer, avoid hitting the mechanical seal 

area directly.  

Unit Storage 

Store the equipment with the cage down if it is going to be out of the water for long periods of time, such 

as during off-season storage. Seals on units that sit upright on a shelf for extended periods of time are 

more likely to dry out. Storing upside down or sideways will ensure oil is reaching the seals and help to 

prevent drying. 

Sacrificial Anode 

All Kasco units include a sacrificial anode installed on the shaft to protect against corrosion and 

electrolysis. Replace the anode if it is reduced to half the original size or if it is white in color. Corrosion 

from electrolysis most commonly occurs in saltwater or brackish water, but it is important to check the 

anode in all installations at least every two to three months.  

Seal And Oil Replacement 

This is a sealed motor assembly. Like brake pads on a car, seals wear out over time. Replace the seals and 

change the oil after three years to increase the motor’s longevity and to avoid more expensive repairs.  

Other Repairs 

Seal replacement and all other repair services should be performed at Kasco or a Kasco-trained 

authorized repair center. Please contact your Kasco distributor or representative to find your nearest 

service center.  

Please keep the original box for maintenance shipping.

MAINTENANCE RECOMMENDATIONS

Back to Contents

Summary of Contents for 3400

Page 1: ...I 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884180 Document version 2022 2 0 J SERIES FOUNTAIN 3400 4400 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 ...

Page 2: ...remium Nozzles Not Included 4 Nozzle Installation 6 Installation Instructions 7 Maintenance Recommendations 8 Troubleshooting Tips 9 Warranty 10 Non Warranty Repairs 11 Repair Contact Form 12 7 16 socket and ratchet 7 16 wrench 11 32 wrench for 8 fasteners 7 16 combination wrench 11 32 wrench 7 16 socket TOOLS AND SUPPLIES NEEDED ...

Page 3: ...ulations including wearing a Personal Flotation Device The unit is supplied with an internal grounding conductor To reduce the risk of electrical shock be certain that the unit is plugged in connected to an approved GFCI protected circuit Means for disconnection must be incorporated in the fixed wiring in accordance with local and national wiring rules Consult a qualified electrician for electrica...

Page 4: ...s Pan Head Screw 4 251220 C 1 4 split washers 7 840537 D 1 4 3 4 OD Flat Washer 10 251300 E 1 4 20 x 1 3 4 Hex Head Bolt 3 475630 F Bottom Screen Section 3 361540 G 1 4 20 Nut 3 840536 H 8 nut 6 771034 I 8 flat washer 12 361543 J 8 x 3 4 screw 6 361545 K Mooring ropes not pictured 2 990700 L Cable ties not pictured 9 415038 Back to Contents ...

Page 5: ...t Width Part No 1 Sequoia Narrow geyser marked S Pre installed 3400 13 8 431230 4400 18 11 2 Linden Center geyser with lower conical pattern 2 piece assembly with bolt 3400 9 29 431232 4400 12 31 3 Birch Wide geyser marked B 3400 7 5 431234 4400 11 8 4 Cypress 1 tier of 12 arcing streams marked C 3400 7 17 431236 4400 9 28 5 Willow Wide arc no nozzle installed 3400 6 5 21 N A 4400 9 31 Sequoia Lin...

Page 6: ...es kascomarine com or your local distributor for order information Mighty Oak Mahogany Magnolia Madrone Pattern Description HP Height Width Part Magnolia 16 2 tiers of 8 arcing streams 3 4 9 29 431325K 1 11 5 37 Mighty Oak 24 3 tiers of 8 arcing streams 3 4 10 24 431335K 1 13 24 Mahogany Center geyser with 16 2 tiers of 8 arcing streams 3 4 11 5 28 431345K 1 14 34 Madrone Center geyser with 12 arc...

Page 7: ...3400 4400 J SERIES FOUNTAIN MANUAL 5 ASSEMBLY INSTRUCTIONS B C D I J I H Align power cord with this notch 1 2 3 4 5 6 G C D D E F Back to Contents ...

Page 8: ...wist to lock the 3 tabs into the nozzle plate NOZZLE INSTALLATION Twist the nozzle into place and insert the quick release pin into one of the holes in the nozzle base plate Quick release pin 1 2 1 2 Standard Nozzle Installation Premium Nozzle Installation Back to Contents ...

Page 9: ...econdary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least 3 feet from the float for every foot of water depth Mooring lines are too short or loose between unit and anchors Back to Contents ...

Page 10: ...s or in other areas prone to buildup such as this inspect and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is still wet If you use a power washer avoid hitting the mechanical seal area directly Unit Storage Store the equipment with the cage down if it...

Page 11: ...ch turns the unit off if it overheats The unit will start up again once it has cooled down If you are noticing these symptoms unplug the equipment immediately to prevent damage to the motor Remove the equipment from the water and inspect for the cause of the problem Some possible causes are low water levels build up preventing heat dissipation through the housing or something stopping the free rot...

Page 12: ...efective part within the warranty period from the date of shipment Customer shall pay shipping charges for returning the unit to Kasco or an Autho rized Repair Center THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED AND ANY OTHER OBLI GATION OR LIABILITY WHATEVER ON THE PART OF KASCO MARINE INC AND IN NO EVENT SHALL KASCO MARINE INC BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL D...

Page 13: ...at are rejected for repair will be destroyed unless otherwise directed by the customer Re jected equipment can be returned at the customer s expense for shipping and handling charges Billing All non warranty repairs will be returned and billed to the customer unless otherwise directed Kasco Marine accepts Visa and MasterCard credit card payments Kasco Marine will call for credit card information u...

Page 14: ...reatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the customer to s...

Reviews: