background image

3400 - 4400 J SERIES FOUNTAIN MANUAL

9

More troubleshooting tips are available in control panel manuals and at www.kascomarine.com. 

“My equipment trips a ground fault protection device.”  

A trip can indicate an electrical service problem, water contamination in the unit, motor issues, and 

problems with the cord, breaker, or control box. Consult Kasco or an electrician to address the issue.

Prior to any consultation, collect this information:  
•  How long does it take to trip the breaker?  

•  Does it always take the same amount of time to trip?  

•  How many times has it tripped?  

•  Have there been any electrical problems in the area recently?  

“My equipment seems to run slowly.” 

The unit may not be receiving proper voltage. This could also indicate a problem with the motor, which 

should be serviced by an authorized repair center. Check that the unit is receiving the proper voltage, 

and contact Kasco for further steps. Note: If the equipment has been stored or exposed to cold for an 

extended period without running, it may take some time for the prop to reach full speed once power is 

supplied.  

“My equipment hums but will not start. When I spin the prop with a stick, it starts up.”

 

This indicates a problem with the starting capacitor. If the equipment is running but the prop is not 

spinning and spinning the prop with a stick starts the unit, then the starting capacitor needs to be 

replaced by an authorized repair center.  

“My equipment turns itself off and back on without the timer and without tripping the breaker.”  

Each Kasco unit is equipped with thermal overload protection, which turns the unit off if it overheats. 

The unit will start up again once it has cooled down. If you are noticing these symptoms, unplug the 

equipment immediately to prevent damage to the motor. Remove the equipment from the water and 

inspect for the cause of the problem. Some possible causes are low water levels, build-up preventing heat 

dissipation through the housing, or something stopping the free rotation of the shaft. If something is 

caught in the unit, or if there is a buildup on the can, remove the debris and clean the equipment.  

“My equipment flow seems to fluctuate and/or be less than usual.” 

 

Most of the time, this symptom is caused by debris clogging the unit. A mat of weeds, leaves, plastic 

bags, etc., can create a clog. If the unit does not have the proper amount of water, the flow or pattern 

will fluctuate and appear sporadic. If you are seeing these symptoms, unplug the unit and clean away the 

debris. While the unit is unplugged, check for another possible cause: a chipped or damaged prop, which 

can cause the unit to wobble in the water. Replace the prop if it is damaged. 

“The breaker trips randomly and sporadically. Sometimes it is a few hours of operation, other times it can be 

days or weeks.”

  

Nuisance trips usually occur when the unit is installed far away from the initial electric service where the 

ground stake is located on the property. It is caused by either induced current in the ground wire or a 

base voltage difference due to soil pH levels. To resolve the problem, contact an electrician and install 

a local grounding stake. This may eliminate the induced current and any base voltage differences. This 

problem can also be caused by unbalanced incoming voltage lines or by a bad breaker or receptacle.

TROUBLESHOOTING TIPS

Back to Contents

Summary of Contents for 3400

Page 1: ...I 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884180 Document version 2022 2 0 J SERIES FOUNTAIN 3400 4400 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 ...

Page 2: ...remium Nozzles Not Included 4 Nozzle Installation 6 Installation Instructions 7 Maintenance Recommendations 8 Troubleshooting Tips 9 Warranty 10 Non Warranty Repairs 11 Repair Contact Form 12 7 16 socket and ratchet 7 16 wrench 11 32 wrench for 8 fasteners 7 16 combination wrench 11 32 wrench 7 16 socket TOOLS AND SUPPLIES NEEDED ...

Page 3: ...ulations including wearing a Personal Flotation Device The unit is supplied with an internal grounding conductor To reduce the risk of electrical shock be certain that the unit is plugged in connected to an approved GFCI protected circuit Means for disconnection must be incorporated in the fixed wiring in accordance with local and national wiring rules Consult a qualified electrician for electrica...

Page 4: ...s Pan Head Screw 4 251220 C 1 4 split washers 7 840537 D 1 4 3 4 OD Flat Washer 10 251300 E 1 4 20 x 1 3 4 Hex Head Bolt 3 475630 F Bottom Screen Section 3 361540 G 1 4 20 Nut 3 840536 H 8 nut 6 771034 I 8 flat washer 12 361543 J 8 x 3 4 screw 6 361545 K Mooring ropes not pictured 2 990700 L Cable ties not pictured 9 415038 Back to Contents ...

Page 5: ...t Width Part No 1 Sequoia Narrow geyser marked S Pre installed 3400 13 8 431230 4400 18 11 2 Linden Center geyser with lower conical pattern 2 piece assembly with bolt 3400 9 29 431232 4400 12 31 3 Birch Wide geyser marked B 3400 7 5 431234 4400 11 8 4 Cypress 1 tier of 12 arcing streams marked C 3400 7 17 431236 4400 9 28 5 Willow Wide arc no nozzle installed 3400 6 5 21 N A 4400 9 31 Sequoia Lin...

Page 6: ...es kascomarine com or your local distributor for order information Mighty Oak Mahogany Magnolia Madrone Pattern Description HP Height Width Part Magnolia 16 2 tiers of 8 arcing streams 3 4 9 29 431325K 1 11 5 37 Mighty Oak 24 3 tiers of 8 arcing streams 3 4 10 24 431335K 1 13 24 Mahogany Center geyser with 16 2 tiers of 8 arcing streams 3 4 11 5 28 431345K 1 14 34 Madrone Center geyser with 12 arc...

Page 7: ...3400 4400 J SERIES FOUNTAIN MANUAL 5 ASSEMBLY INSTRUCTIONS B C D I J I H Align power cord with this notch 1 2 3 4 5 6 G C D D E F Back to Contents ...

Page 8: ...wist to lock the 3 tabs into the nozzle plate NOZZLE INSTALLATION Twist the nozzle into place and insert the quick release pin into one of the holes in the nozzle base plate Quick release pin 1 2 1 2 Standard Nozzle Installation Premium Nozzle Installation Back to Contents ...

Page 9: ...econdary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least 3 feet from the float for every foot of water depth Mooring lines are too short or loose between unit and anchors Back to Contents ...

Page 10: ...s or in other areas prone to buildup such as this inspect and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is still wet If you use a power washer avoid hitting the mechanical seal area directly Unit Storage Store the equipment with the cage down if it...

Page 11: ...ch turns the unit off if it overheats The unit will start up again once it has cooled down If you are noticing these symptoms unplug the equipment immediately to prevent damage to the motor Remove the equipment from the water and inspect for the cause of the problem Some possible causes are low water levels build up preventing heat dissipation through the housing or something stopping the free rot...

Page 12: ...efective part within the warranty period from the date of shipment Customer shall pay shipping charges for returning the unit to Kasco or an Autho rized Repair Center THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED AND ANY OTHER OBLI GATION OR LIABILITY WHATEVER ON THE PART OF KASCO MARINE INC AND IN NO EVENT SHALL KASCO MARINE INC BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL D...

Page 13: ...at are rejected for repair will be destroyed unless otherwise directed by the customer Re jected equipment can be returned at the customer s expense for shipping and handling charges Billing All non warranty repairs will be returned and billed to the customer unless otherwise directed Kasco Marine accepts Visa and MasterCard credit card payments Kasco Marine will call for credit card information u...

Page 14: ...reatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the customer to s...