background image

TWO YEAR LIMITED WARRANTY: 

Kasco Marine, Inc. warrants the C-10 Thermostat 
Control to be free from defects in material and work-
manship under normal use and service.  The Kasco 
Marine, Inc. obligation under this warranty is limited 
to replacing free of charge any defective part within 
two (2) years from date of purchase.  Customer shall 
pay all shipping charges. 
 
THIS WARRANTY IS IN LIEU OF ANY OTHER 
WARRANTIES EXPRESS OR IMPLIED, AND 
ANY OTHER OBLIGATION OR LIABILITY 
WHATEVER ON THE PART OF KASCO MA-
RINE, INC.  AND IN NO EVENT SHALL KASCO 
MARINE, INC. BE LIABLE FOR ANY SPECIAL 
OR CONSEQUENTIAL DAMAGES. 
 
No warranty registration is required, only original 
purchase receipt is needed for limited warranty cover-
age. 
    

Warranty is void

: If thermostat is damaged by unau-

thorized tampering or improper use. 
 
 
 

KASCO SERVICE PARTS: 

If the service parts listed below are not available from 
your local marine dealer, please order direct from Kasco 
Marine. 
 
F2400 (1/2 HP) “K” Propeller 
F3400 (3/4 HP) “J” Propeller 
4400 (1 HP) “M” Propeller 
Zinc Anode 
Electric Power Cable, 25’ length (16 gauge) 

Other lengths and gauges are available by special order. 

 
Specifications are subject to change without prior notice. 
 
All orders shipped via United Parcel Service. 
 
 
 
 
 
For Optional Kasco Parts or accessories, contact your lo-
cal dealer or call Kasco Marine, Inc. at (715) 262-4488. 

The Industry Leader in  

Ice Control Engineering. 

 

KASCO MARINE, INC.

   

800 Deere Road  

Prescott, WI 54021-1241 

 

Phone (715) 262-4488 *  Fax (715) 262-4487 

 

www.De-Icer.com  *  [email protected] 

12 

Summary of Contents for 2400D

Page 1: ...Warranty Claim Return Policy Maintenance Recommendations De Icer Installation Instructions Specs Sizing Replacement Parts Assembly Diagram C 10 Instructions C 20 Instructions Universal Dock Mount Ins...

Page 2: ...when operating NEVER run the unit out of water It will damage the seals and create a dangerous situation for the operator Extreme caution should be used around open water especially cold water which p...

Page 3: ...vironments such as in marinas or other commercial applications or on demand use as may be needed Your Kasco Marine De Icer is ready for immediate use after installation The motor is of an oil filled d...

Page 4: ...eriodically and replaced if necessary Note There are certain conditions under which no circulator can prevent ice damage such as ice that moves due to wind or current extremely cold weather where ice...

Page 5: ...Kasco Marine will re turn units repaired under warranty at our expense via ground freight within the continental United States Other Repairs Most failed equipment can be repaired at substantially low...

Page 6: ...t stagnant water areas and poor water quality If you do decide to store the unit during non freezing times it is not necessary to store Kasco motors upside down All internal seals are fully lubricated...

Page 7: ...lifting or a combination of lifting expansion is your concern you may wish to keep your dock structure or boat area completely ice free Both of these concerns or objectives are very different and may...

Page 8: ...the bow to the stern with the least resistance It is generally easier to De Ice a boat by installing the De Icer at or near the bow angled to push the De Icing flow of wa ter toward the stern It is ge...

Page 9: ...TEP SIX OPTIONAL On installations where open water area is required or de sired to be limited controlled a curtain technique can be used to block the flow of water and restrict the open wa ter area By...

Page 10: ...0280 SEALING PLUG 1 3 990285 SEALING WASHER 1 4 243475 ZINC ASSEMBLY 2400 3400 MODELS 1 4A 840475 ZINC ASSEMBLY 4400 MODELS 1 5 240170 2400 K PROP 2400 MODEL 1 5A 340125 3400 J PROP 3400 MODEL 1 5B 44...

Page 11: ...ough to your power supply to allow at least a slight slack in the power cord from the C 10 Select the screw s with which to mount your C 10 You will need two for the mounting holes at the top of the b...

Page 12: ...ase receipt is needed for limited warranty cover age Warranty is void If thermostat is damaged by unau thorized tampering or improper use KASCO SERVICE PARTS If the service parts listed below are not...

Page 13: ...ogramming of the timer and thermostat see Programming below Install the De Icer power cord through the hole in the lower left portion of the C 20 housing and plug it into the receptacle inside the C 2...

Page 14: ...nd operate only on temperature pull all trippers on the timer to the ON position Bypassing the thermostat to operate only on time can only be done when temperatures are below 40O F To do so set the th...

Page 15: ...sco urges that the base be mounted as securely as possible For salt water use Kasco suggests that you use 1 stainless steel pipe STEP ONE Determine the most suitable application for your situation Ins...

Page 16: ...e sure all bolts and nuts are now tight If more than one set of holes align use the holes closest to the de icer STEP SEVEN Place the Clam Shell Pipe Clamp onto the pipe extension Make sure the two ha...

Page 17: ...Position the Float upside down lengthwise channels facing up and place the Base Strap so the three holes in the Base Strap align with the three threaded holes that comprise the lengthwise midline of t...

Page 18: ...d be on the side of the U Bracket that is closer to the cord clamp Tighten the hardware using the 7 16 wrench and socket wrench until the U Bracket clamps firmly around the cage U Bracket should pull...

Page 19: ...nd of the motor At this time use the Nylon Tie provided to connect the power cord and front Rope to prevent the cord from tangling in the prop Also if the power cord has a Quick Dis connect and Additi...

Page 20: ...rt back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit s...

Page 21: ...or by the customer You must include the power cord and cage assembly with each unit sent in for repair to be considered for warranty repair Do not ship the float and or control box with the unit for r...

Page 22: ...gister your Kasco De Icer online at www de icer com solutions_warranty_registration htm Also fill in the information below and keep for your records Model Ex 2400D _______________________________ Seri...

Reviews: