THE APPLIANCE IS LEAKING:
Make sure the appliance is working in good condition and does not tilt in position.
If you are not using continuous drainage, make sure the water tank is empty or not full.
There may be water remain in the water tank as a result of the water evaporation during the
dehumidifying test carried out in the factory.
THE APPLIANCE HAS MUSTY-ODOR
Due to the temperature rising of heat exchanger, the air may have some strange smell at the
beginning.
SPECIFICATIONS
Model No.
Rated Voltage & Frequency
KDH2016
220 - 240V~ 50Hz
Refrigerant
R134a
Suction/Discharge Pressure
3.0/1.8MPa
Waterproof Grade
IP21
Input Power
385W
Input Power
315W
At 30ºC, 80% R.H.:
Dehumidifying Capacity
20L/day
At 26.7ºC, 60% R.H.:
Dehumidifying Capacity
12L/day
Net Weight
Dimension (W x D x H) mm
Temp. Range For Use
Water Tank Capacity
15kg
367 x 246 x 582
5ºC - 35ºC
3.5L