TROUBLESHOOTING

THE APPLIANCE DOES NOT OPERATE: 

Is the appliance plugged in? 
Is the house electricity on? 
Is the room temperature below 5ºC or above 35ºC? If so, it is out of the working range of the
appliance. 
Ensure the ON/OFF switch is turned on. 
Check the water tank if it is positioned properly in the appliance, and make sure it is not full. 
Make sure the air inlet and outlet are not obstructed. 

THE APPLIANCE SEEMS TO DO NOTHING: 

Q: Is the filter dusty or contaminated?  
A: Remove the filter and clean it with warm water (below 40ºC) every 2 weeks. Let it dry
     naturally and replace it.  
Q: Is the air intake or outlet blocked up? 
A: Please move the object away from the air intake or outlet. 
Q: Is the room humidity already quite low? 
A: The dehumidifier shall not operate if the humidity setting is higher than the ambient
     humidity.
Q: Is the room temperature too low?
A: The appliance will start to defrost from 5ºC-15ºC. Compressor will stop for a brief period
     of time (fan will operate in high fan speed). When it finishes defrosting, it will be back to
     normal operation. 

THE APPLIANCE SEEMS TO OPERATE NON-STOP:

Q: Do the windows or doors open? 
A: Please close the windows or doors when operating the dehumidifier. 
Q: Is the area to be dehumidified too large for the capacity of the appliance? 
A: Limit the area to dehumidify.  
Q: Is there something in the room producing lots of humidity? 
A: Please put these stuffs into another room, close the toilet lid and cover every glass of water. 

THE APPLIANCE IS TOO NOISY: 

Noise will rise if compressor has just started. 
Power supply problem.
Check whether the appliance is standing on a level surface. 
During operation or changing modes, there is a swooshing sound. This is due to the sound of the
flow of refrigerant and is normal.  
There might be some noise if the appliance is operating on wooden floor. 

Summary of Contents for KDH2016

Page 1: ...Dehumidifier User Manual Model KDH2016 Before operating the appliance please read this manual and all the safety instructions thoroughly and retain it for future reference...

Page 2: ...CONTENT PAGE SAFETY INSTRUCTION 1 2 2 3 7 8 9 10 PARTS DESCRIPTION CONTROL PANEL OPERATION INSTRUCTION MAINTENANCE INSTRUCTION TROUBLESHOOTING SPECIFICATION WARRANTY...

Page 3: ...the right place in order to avoid tripping the appliance over Do not put any objects on the appliance or put the appliance below a socket outlet Please keep the air inlet and the air outlet unblocked...

Page 4: ...e Air Inlet Water Tank Fixing Hole Of Power Cord Power Cord Float Correct Position Wrong Position 2 CONTROL PANEL Fan Speed Indicator Filter Clean Indicator Mode Indicator Water Tank Full Indicator LC...

Page 5: ...will stop operation by the preset time Note Press the timer button to increase the set auto on off time until it has turned back to 00h to cancel the timer setting The timer indicator will be off Humi...

Page 6: ...ance will return to standby mode and you can restart the operation by pressing the ON OFF button The operational temperature range of this appliance is 5 C 35 C If the plug and power supply are in nor...

Page 7: ...the appliance Take off the drain cover and remove the drainage plug in anti clockwise direction Fig 4 drain cover drainage plug Fig 4 5 2 Empty the water tank Fig 2 Fig 2 Fig 1 3 Insert the water tank...

Page 8: ...tube periodically to see whether they are connected tightly and whether they are damaged or blocked Fig 6 Please purchase the water tube separately drainage drain outlet adapter drainage gasket Fig 5...

Page 9: ...and let it dry naturally Insert the clasp at the lower part of the air filter into the appliance and then press the air filter downwards until you have heard a sound After that re assemble the panel D...

Page 10: ...ent humidity Q Is the room temperature too low A The appliance will start to defrost from 5 C 15 C Compressor will stop for a brief period of time fan will operate in high fan speed When it finishes d...

Page 11: ...he factory THE APPLIANCE HAS MUSTY ODOR Due to the temperature rising of heat exchanger the air may have some strange smell at the beginning SPECIFICATIONS Model No Rated Voltage Frequency KDH2016 220...

Page 12: ...ISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT INCLUDING WITHOUT LIMITATION DAMAGES FOR INJURY LOSS OF PROPERTY BUSINESS PROFITS BUSINESS INTERRUPTION OR FROM ANY BREACH OF WARRANTY EVEN IF OUR...

Reviews: