Karma 622 User Manual Download Page 7

5

12

CLEANING

ONCE DAILY:

1. Open the door and turn OFF the concentrate switch.
2. Using large vessel, dispense approximately 1 liter of water on each side.
3. Turn the concentrate switch ON and close door.
4. Clean the drip tray and the tray insert with a solution of mild dishwashing detergent and rinse 

with hot water.

5. Wipe down the exterior cabinetry with a clean damp cloth.

WEEKLY:

1. Open front door and disassemble each fitment from the BIB’s and remove the fitment from the syrup lines.
2. Place each syrup line in at least 2 liters of a solution of 100° F water and dishwashing soap.
3. Turn the concentrate switch OFF and turn the concentrate switch ON.
4. Press each dispense handle until solution has flushed all concentrate from each syrup line.
5. Rinse each syrup line with at least 1 liter of 100°F water.
6. Mix a solution of US Chemical Sanitizer or equivalent equal to 100 parts per million chlorine into one gallon 

of 100°F water.

7. Press each handle and dispense one half gallon of sanitizer per syrup line.
8. Wash the fitments in a solution of 100°F water dishwashing detergent.
9. Rinse the fitment and soak for 3 minutes in a solution of US Chemical Sanitizer or equivalent equal to 100 

parts per million chlorine into one gallon of 100°F water.

10. Allow pars to air dry before reassembling fitments to tubing.
11. Reassemble fitments to B.I.B. packs.
12. Dispense each product until concentrate is primed thru each spout.
13. Turn the water switch to the ON position and close the door.

EVERY 6 MONTHS REPLACE THE CONCENTRATE TUBING.

Summary of Contents for 622

Page 1: ...TIONS DIMENSIONS Overall 9 W x 26 D x 28 H CONSTRUCTION All Stainless Steel Cabinetry ELECTRICAL 115 V 50 60 HZ 12amps or 208 240 V 50 60 HZ 12 amps 240V PLUMBING 1 4 Waterline Filters WATER RESERVOIR...

Page 2: ...CE COMPONENTS WITHOUT UNPLUGGING ELECTRICAL CORD CAUTION WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY CONNECTED TO A PORTABLE WATER SUPPLY SHALL BE SIZED INSTALLED AND MAINTAINED ACCORDING TO FEDERAL...

Page 3: ...ction on the 115 V model requires a minimum 15 amp outlet for the line cord to be plugged into 3 To connect this machine to 240V cut the current plug off and replace with 240V plug or hard wire Hook b...

Page 4: ...S SHIPPED WITH PUMP ROTORS IN THE UNLOCKED POSITION PRIOR TO PRIMING LOCK BOTH PUMP ROTORS See Figure 2 2 Open the door and load both product packs into the dispenser Assemble the fitment to each prod...

Page 5: ...cifically describing any defect promptly after discovery KARMA reserves the right or inspect products claimed to be defective and covered by warranty either at Purchaser s location or at KARMA s princ...

Page 6: ...Fig 7 The machine has been factory set to the ratio defined at time of ordering To change this ratio you must first slow thr awa ter flow by turning the adjustment knob clockwise This knob may be fou...

Page 7: ...ispense handle until solution has flushed all concentrate from each syrup line 5 Rinse each syrup line with at least 1 liter of 100 F water 6 Mix a solution of US Chemical Sanitizer or equivalent equa...

Page 8: ...ump tubing A Water and or concentrate pump sped adjust ment required B Incorrect pump tubing used A If the dispenser was shut off a 25 minute heat up time is required A Syrup line has loose connection...

Page 9: ...7 10...

Page 10: ...9 8...

Reviews: