START UP

1. Press the POWER SWITCH to the ON position after connecting

the electrical source and plumbing source. The tank will auto-
matically fill and the heater will come on when the water level 
covers the heater and reaches the lower sensor probe.

NOTE: YOUR MODEL 622 IS SHIPPED WITH PUMP ROTORS IN
THE UNLOCKED POSITION. PRIOR TO PRIMING, LOCK BOTH
PUMP ROTORS (See Figure 2).

2. Open the door and load both product packs into the dispenser. 

Assemble the fitment to each product pack.

3. To prime, press the water switch to the OFF position and put 

the product switch to the ON position. To prime each side, 
press dispense for each side until the product is visually 
through all the tubing to the dispense spout. Turn the water 
on. (Fig. 3)

Fig. 2

Fig. 3

- NOTES -

Summary of Contents for 622

Page 1: ...TIONS DIMENSIONS Overall 9 W x 26 D x 28 H CONSTRUCTION All Stainless Steel Cabinetry ELECTRICAL 115 V 50 60 HZ 12amps or 208 240 V 50 60 HZ 12 amps 240V PLUMBING 1 4 Waterline Filters WATER RESERVOIR...

Page 2: ...CE COMPONENTS WITHOUT UNPLUGGING ELECTRICAL CORD CAUTION WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY CONNECTED TO A PORTABLE WATER SUPPLY SHALL BE SIZED INSTALLED AND MAINTAINED ACCORDING TO FEDERAL...

Page 3: ...ction on the 115 V model requires a minimum 15 amp outlet for the line cord to be plugged into 3 To connect this machine to 240V cut the current plug off and replace with 240V plug or hard wire Hook b...

Page 4: ...S SHIPPED WITH PUMP ROTORS IN THE UNLOCKED POSITION PRIOR TO PRIMING LOCK BOTH PUMP ROTORS See Figure 2 2 Open the door and load both product packs into the dispenser Assemble the fitment to each prod...

Page 5: ...cifically describing any defect promptly after discovery KARMA reserves the right or inspect products claimed to be defective and covered by warranty either at Purchaser s location or at KARMA s princ...

Page 6: ...Fig 7 The machine has been factory set to the ratio defined at time of ordering To change this ratio you must first slow thr awa ter flow by turning the adjustment knob clockwise This knob may be fou...

Page 7: ...ispense handle until solution has flushed all concentrate from each syrup line 5 Rinse each syrup line with at least 1 liter of 100 F water 6 Mix a solution of US Chemical Sanitizer or equivalent equa...

Page 8: ...ump tubing A Water and or concentrate pump sped adjust ment required B Incorrect pump tubing used A If the dispenser was shut off a 25 minute heat up time is required A Syrup line has loose connection...

Page 9: ...7 10...

Page 10: ...9 8...

Reviews: