Karma 622 User Manual Download Page 5

3

14

TIMER ADJUSTMENT

1.  Remove plugs from correct hole on front of dispenser. (See Fig. 4)

Note: Four Timer holes; On the left the small one is on top, the large one is on bottom

On the right the small one is on top, the large one is on bottom

2. Adjust by using a small flat blade screwdriver . Turn timer stems clockwise to increase or 

counterclockwise to decrease the time range.  (See Fig. 5) 

WARRANTY

Karma warrants, except as hereinafter provided, as follows:

1. That each product sold hereunder which is manufactured by KARMA shall be free of defects in materials or workmanship

for a period of 1 year after shipment thereof. This warranty is void in cases of damage in transit, negligence, faulty 
installation, abuse, abnormal usage, misuse, accidents, or failure to maintain the product according to the instruction 
manual provided. This warranty does not cover malfunctions due to dirty or clogged waterlines, lime-related conditions or
other conditions related to the local water supply. THERE IS NO OTHER EXPRESS WARRANTY; KARMA HERBY 
DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND
FITNESS FOR ANY PARTICULAR PURPOSE INDICATED BY PURCHASER TO KARMA.

2. The sole obligation of KARMA hereunder shall be limited to repair or replacement, at the option of KARMA, of any 

defec tive products expressly warranted under the terms of this Agreement. This obligation does not include the cost or 
expense of travel time by service personnel, but does include the cost or expense of actual time spent to remove and 
replace a defective part or product. This obligation shall be conditioned upon receipt of KARMA of written notice 
specifically describing any defect promptly after discovery. KARMA reserves the right or inspect products claimed to be 
defective and covered by warranty, either at Purchaser’s location or at KARMA’s principal place of business in 
Watertown, Wisconsin, freight pre-paid; the place of such inspection to be determined solely at the option of KARMA. 
Final determination as to whether a product is actually defective rests with KARMA. A defective product shall not be 
otherwise returned to KARMA unless 

specifically authorized by KARMA.

3. KARMA will not assume responsibility, pay expenses or accept invoices for unauthorized service, repairs, or replacement 

with respect to its products, even if defective. KARMA assumes no liablity for labor charges incidental to the adjustment, 
service, repairing, removal or replacement of its products, or for the expense of repairs or any other direct or indirect
costs incurred by Purchaser with respect to such products, except when approved in advance by KARMA.

LIMITATION OF LIABILITY

NO CLAIMS MADE HEREUNDER BY THE PURCHASER, WHETHER AS TO GOODS DELIVERED OR FOR NONDELIVERY
SHALL BE GREATER THAN THE PURCHASE PRICE OF THE GOODS IN RESPECT OF WHICH SUCH CLAIM IS MADE.
KARMA SHALL UNDER NO CIRCUMSTANCES BE LIABLE FOR ANY LOSS OF PROFITS OR ANY OTHER INCIDENTAL
OR CONSEQUENTIAL DAMAGES, OR FOR DAMAGES IN THE NATURE OF PENALTIES.

365 DAYS/24 HOUR FAX BACK SERVICE

TO QUICKLY OBTAIN COPIES OF ONE OR MORE OF THE PAGES OF THIS MANUAL, CALL 1-800-
558-9565 OR 920-261-1424 AND SELECT EXT.152 ON KARMA’S GREETING MENU. THEN FOLLOW
THE VOICE PROMPT INSTRUCTION TO HAVE THE DESIRED INFORMATION AUTOMATICALLY
FAXED BACK TO YOU.

Fig. 4

Fig. 5

NOTE:

1. The standard time ranges allow for vessel sizes from 25 ozs. to 75 ozs.

2. Partial vessel sizes can be obtained simply by depressing the brew switch 

during a brew cycle.

TIMER

HOLES

Summary of Contents for 622

Page 1: ...TIONS DIMENSIONS Overall 9 W x 26 D x 28 H CONSTRUCTION All Stainless Steel Cabinetry ELECTRICAL 115 V 50 60 HZ 12amps or 208 240 V 50 60 HZ 12 amps 240V PLUMBING 1 4 Waterline Filters WATER RESERVOIR...

Page 2: ...CE COMPONENTS WITHOUT UNPLUGGING ELECTRICAL CORD CAUTION WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY CONNECTED TO A PORTABLE WATER SUPPLY SHALL BE SIZED INSTALLED AND MAINTAINED ACCORDING TO FEDERAL...

Page 3: ...ction on the 115 V model requires a minimum 15 amp outlet for the line cord to be plugged into 3 To connect this machine to 240V cut the current plug off and replace with 240V plug or hard wire Hook b...

Page 4: ...S SHIPPED WITH PUMP ROTORS IN THE UNLOCKED POSITION PRIOR TO PRIMING LOCK BOTH PUMP ROTORS See Figure 2 2 Open the door and load both product packs into the dispenser Assemble the fitment to each prod...

Page 5: ...cifically describing any defect promptly after discovery KARMA reserves the right or inspect products claimed to be defective and covered by warranty either at Purchaser s location or at KARMA s princ...

Page 6: ...Fig 7 The machine has been factory set to the ratio defined at time of ordering To change this ratio you must first slow thr awa ter flow by turning the adjustment knob clockwise This knob may be fou...

Page 7: ...ispense handle until solution has flushed all concentrate from each syrup line 5 Rinse each syrup line with at least 1 liter of 100 F water 6 Mix a solution of US Chemical Sanitizer or equivalent equa...

Page 8: ...ump tubing A Water and or concentrate pump sped adjust ment required B Incorrect pump tubing used A If the dispenser was shut off a 25 minute heat up time is required A Syrup line has loose connection...

Page 9: ...7 10...

Page 10: ...9 8...