P3 Group :Auxiliary running parameter

Func

Code

Name

Range

Min

Unit

Factory

default

Modify

P3.01

Parameter initialization

setting

LED unit’s digit:

0: All parameters are allowed to be

modiFied.

1: All parameters are not allowed to

be

modiFied except this parameter

itself.

2: All parameters are not allowed to

be

modiFied except P0.02 parameter

and

this parameter itself

LED ten’s digit:

0

Inaction

1

Factory default reset

2

Clear history fault record

1

0

×

P4 Group: Terminal control function parameter
Func

Code

Name

Range

Min

Unit

Factory

default

Modify

P4.00

Input terminal X1

function selection

0

Idle terminal

1

Multi-stage speed control terminal 1

2

Multi-stage speed control terminal 2

3

Multi-stage speed control terminal 3

4

External FWD JOG control input

5

External REV JOG control input

6

Acc/Dec time terminal 1

7

Acc/Dec time terminal 2

8

Acc/Dec time terminal 3

9

3-wire control

10

Free stop input (FRS)

11

External stop command

12

Stopping DC brake input command

DB

13

Inverter running prohibited

14

Freq. increase command(UP)

15

Freq. decrease command(DOWN)

16

Acc/Dec prohibited command

17

External reset input (clear fault)

18

Peripheral equipment fault input

(normally open)

19

Freq. control channel selection 1

20

Freq. control channel selection 2

21

Freq. control channel selection 3

22

Command switched to terminal

23

Running command control mode

selection 1

24

Running command control mode

selection 2

25

Swing frequency selection

26

Swing frequency running reset

27

Close loop invalid

28

Simple PLC pause running command

29

PLC invalid

30

PLC Reset in stopping state

31

Freq. switch to CI

32

Counter trig signal input

33

Counter clear input

34

External interrupt input

35

Pulse freq. input (only valid for X6)

36: fire mode

1

0

×

P4.01

Input terminal X2

function selection

Ditto

1

0

×

P4.02

Input terminal X3

function selection

Ditto

1

0

×

Summary of Contents for KD3000 Series

Page 1: ...KD3000 Series Mini Inverter Simple Manual 6w 200w Mini Inverter Green Intelligent Energy Saving Shenzhen Karda Electric Co Ltd www szkarda com...

Page 2: ...the input power is off Be sure to install the terminal cover before turning on the power When removing the cover be sure to turn off the power Grounding terminal must be grounded reliably Do not touc...

Page 3: ...put Terminals U V W 220V 3 Phase output Terminals Grounding V Basic Wiring Diagram Sort Terminal Name Function Description Specification Communi cation 485 RS485 communication port RS485 differential...

Page 4: ...rogramming see terminal function parameters P4 group input terminal functions Common port COM X2 Multifunctional input terminal 2 X3 Multifunctional input terminal 3 Power source 10V 10Vpower source S...

Page 5: ...on control panel single display valid 1 key on control panel single display valid Panel digital potentiometer key on control panel double display valid 2 Digital setting 1 control panel given 3 Digit...

Page 6: ...80 0 Acc Dec time P0 14 P0 15 90 0 1 60 0 P0 16 Acc Dec time unit 0 Second 1 Minute 0 0 P0 17 Acc time 1 0 1 6000 0 0 1 20 0 P0 18 Dec time 1 0 1 6000 0 0 1 20 0 P0 19 Upper limit freq Lower limit fre...

Page 7: ...start from start freq 2 Track speed then start 1 0 P2 01 Start freq 0 40 20 00Hz 0 01Hz 0 50Hz P2 02 Start freq running duration 0 0 30 0s 0 1s 0 0s P2 03 DC brake current as start 0 15 1 0 P2 04 DC...

Page 8: ...7 Acc Dec time terminal 2 8 Acc Dec time terminal 3 9 3 wire control 10 Free stop input FRS 11 External stop command 12 Stopping DC brake input command DB 13 Inverter running prohibited 14 Freq increa...

Page 9: ...ction parameter Func Code Name Range Min Unit Factory default Modify P6 00 Last fault record Last fault record 1 0 P6 01 Output freq in last fault Output freq in last fault 0 01Hz 0 P6 02 Set freq in...

Page 10: ...too big Add suitable braking device Inverter capacity is too low Select inverter with proper capacity E 03 Over current at constant speed running Load mutation Check load Acc or Dec time is too short...

Page 11: ...ns voltage General motor runs at low speed with heavy load for long term Use a special motor for long term running Wrong setting of motor overload protection factor Set the factor right Motor chocked...

Page 12: ...ll input power source filter DSP read write error Reset or contact supplier E 17 EP2PPROM error Read write error of control parameter press key to reset or install input power source filter E 18 Motor...

Page 13: ...of fault and clearing otherwise the inverter may be damaged 2 If it can t be reseted or fault occurs again after reset please check the cause of fault continuous reset may damage inverter 3 Reset the...

Reviews: