P1 Group: Frequency setting function parameter

Func

Code

Name

Range

Min

Unit

Factory

default

Modify

P1.00

Analog Filtering time

constant

0.01

30.00s

0.01s

0.20s

P1.06

CI channel gains

0.01

9.99

0.01

1.00

P1.07

CI min given

0.00

P1.09

0.01V

0.00V

P1.08

Corresponding freq. to

CI min given

0.00

Upper limit freq

0.01Hz

0.00Hz

P1.09

CI max given

P1.07

10.00V

0.01V

10.00V

P1.10

Corresponding freq.to

CI max given

0.00

Upper limit freq

0.01Hz

50.00Hz

P0.12

Carrier freq

1.0K

14.0K

0.1K

8.0K

×

P0.13

Acc/Dec mode

selection

0

Linear Acc/Dec

1

Curve Acc/Dec

1

0

×

P0.14

Time of S curve

start stage

10.0

%~

50.0

%(

Acc/Dec time

P0.14

P0.15

90

0.1

20.0

P0.15

Time of S curve

ascent stage

10.0

%~

80.0

%(

Acc/Dec time

P0.14

P0.15

90

0.1

60.0

P0.16

Acc/Dec time unit

0

Second

1

Minute

0

0

×

P0.17

Acc time 1

0.1

6000.0

0.1

20.0

P0.18

Dec time 1

0.1

6000.0

0.1

20.0

P0.19

Upper limit freq.

Lower limit freq. ~Max output freq.P0.06

0.01Hz

50.00Hz

×

P0.20

Lower limit freq.

0.00Hz

Upper limit freq.

0.01Hz

0.00Hz

×

P0.21

Lower limit freq.

Running mode

0

Running at lower limit freq

1

Stopping

1

0

×

P0.22

V/F curve setting

0

Constant torque curve

1

Reduced torque curve 1 (1.2 times the

power)

2

Reduced torque curve 2 (1.7 times the

power)

3

Reduced torque curve 3 (2.0 times the

power)

4

Customized V/F curve

1

0

×

P0.23

V/F Freq.valueP3

P0.25

P0.07 Basic running freq.

0.01Hz

0.00Hz

×

P0.24

V/F Volt.valueV3

P0.26

100.0

0.1

0.0

×

P0.25

V/F Freq.valueP2

P0.27

P0.23

0.01Hz

0.00Hz

×

P0.26

V/F Volt.valueV2

P0.28

P0.24

0.1

0.0

×

P0.27

V/F Freq.valueP1

0.00

P0.25

0.01Hz

0.00Hz

×

V/F Volt.valueV1

0

P0.26

0.1

0.0

×

Summary of Contents for KD3000 Series

Page 1: ...KD3000 Series Mini Inverter Simple Manual 6w 200w Mini Inverter Green Intelligent Energy Saving Shenzhen Karda Electric Co Ltd www szkarda com...

Page 2: ...the input power is off Be sure to install the terminal cover before turning on the power When removing the cover be sure to turn off the power Grounding terminal must be grounded reliably Do not touc...

Page 3: ...put Terminals U V W 220V 3 Phase output Terminals Grounding V Basic Wiring Diagram Sort Terminal Name Function Description Specification Communi cation 485 RS485 communication port RS485 differential...

Page 4: ...rogramming see terminal function parameters P4 group input terminal functions Common port COM X2 Multifunctional input terminal 2 X3 Multifunctional input terminal 3 Power source 10V 10Vpower source S...

Page 5: ...on control panel single display valid 1 key on control panel single display valid Panel digital potentiometer key on control panel double display valid 2 Digital setting 1 control panel given 3 Digit...

Page 6: ...80 0 Acc Dec time P0 14 P0 15 90 0 1 60 0 P0 16 Acc Dec time unit 0 Second 1 Minute 0 0 P0 17 Acc time 1 0 1 6000 0 0 1 20 0 P0 18 Dec time 1 0 1 6000 0 0 1 20 0 P0 19 Upper limit freq Lower limit fre...

Page 7: ...start from start freq 2 Track speed then start 1 0 P2 01 Start freq 0 40 20 00Hz 0 01Hz 0 50Hz P2 02 Start freq running duration 0 0 30 0s 0 1s 0 0s P2 03 DC brake current as start 0 15 1 0 P2 04 DC...

Page 8: ...7 Acc Dec time terminal 2 8 Acc Dec time terminal 3 9 3 wire control 10 Free stop input FRS 11 External stop command 12 Stopping DC brake input command DB 13 Inverter running prohibited 14 Freq increa...

Page 9: ...ction parameter Func Code Name Range Min Unit Factory default Modify P6 00 Last fault record Last fault record 1 0 P6 01 Output freq in last fault Output freq in last fault 0 01Hz 0 P6 02 Set freq in...

Page 10: ...too big Add suitable braking device Inverter capacity is too low Select inverter with proper capacity E 03 Over current at constant speed running Load mutation Check load Acc or Dec time is too short...

Page 11: ...ns voltage General motor runs at low speed with heavy load for long term Use a special motor for long term running Wrong setting of motor overload protection factor Set the factor right Motor chocked...

Page 12: ...ll input power source filter DSP read write error Reset or contact supplier E 17 EP2PPROM error Read write error of control parameter press key to reset or install input power source filter E 18 Motor...

Page 13: ...of fault and clearing otherwise the inverter may be damaged 2 If it can t be reseted or fault occurs again after reset please check the cause of fault continuous reset may damage inverter 3 Reset the...