3
1 Display
2 ADVANCE key
The dosing pump must be dearated if the
pump has sucked in air (for e.g. if the dos-
ing container has been completely emp-
tied).
–
The unit will stop; the display shows the
interruption "Motor protection".
Note
This errror message is displayed independ-
ent of which dosing container has been
used.
1 Dosing frequency button
2 Screw connections
3 Dosing pump
Refill dosing station (refer chapter on
Startup)
Loosen screws on the dosing pump.
Read and note the dosing frequency
that has been set at the LEDs of the
dosing pump.
Set the dosing frequency to 100% by
repeatedly pressing the dosing fre-
quency button and waiting until there
are no more bubbles in the suction pipe.
Tighten the screws.
Set the dosing pump to the original dos-
ing frequency.
1 Return key
Accept the interruption message on the
operating panel by pressing the Return
key; the unit will start.
Check the pressure difference between the
two manometers. If the difference is more
than 0.08 MPa, then change the filter inlay:
1 Manometer
2 Filter inlay
3 Seal
4 Filter pot
5 Filter key
Switch off the plant using the "ON/OFF"
key.
Interrupt raw water inflow.
Briefly switch on the unit by pressing
the "ON/OFF" key until the pressure in
the initial filter reduces.
Switch off the plant using the "ON/OFF"
key.
Insert the filter key at the filter pot and
unscrew the filter pot.
Remove the filter inlay from the filter pot
und insert a new filter inlay in the filter
pot.
Check sealing ring for damage and re-
place if required.
Maintenance schedule
Time
Check / Activity
Target value
In case of deviation
daily
Filling level of dosing container
adequate filling
refill
Air bubbles in the dosing pipes
no air bubbles
Bleed dosing pump.
Drinking water flow based on the startup value
Lowered by less than 10%
Fine regulation
Drinking water guide value based on the startup
value
Increase within 10%
Fine regulation
Pressure difference between pump and concen-
trate pressure
maximum 15% above startup difference
Kärcher Customer Ser-
vice
Counter/meter for media and active carbon filters Reflushing has taken place in the last 24
hours
Kärcher Customer Ser-
vice
Pressure difference fine filter
maximum 0;.08 MPa
Replace fine filter
Visual inspection of the plant
no leaks
Kärcher Customer Ser-
vice
weekly
Fill up operations log
monthly
Clean and rinse dosing container
Visual inspection of raw water pump
No damage/ leaks can be detected
Kärcher Customer Ser-
vice
Float switch in drinking water tank
no functional disruption can be detected
Kärcher Customer Ser-
vice
Maintenance Works
Check media and active carbon filters
ADVANCE Display
–
current time
5 s
Regeneration time
short
Number of regenerations
short
Days and hours since the
last regeneration
–
current time
Bleed dosing pump.
Replace fine filter
14
EN
Summary of Contents for WPC 600 BW
Page 2: ...2...
Page 64: ...8 WPC B 1 024 dH C S cm h MPa MPa MPa l h S cm ____ 64 EL...
Page 65: ...9 WPC A 1 024 h dH S cm pH pH C MPa MPa MPa MPa MPa MPa MPa MPa l h l h S cm K rcher 65 EL...
Page 83: ...9 WPC B 1 024 dH C a a ____ 83 RU...
Page 84: ...10 WPC A 1 024 dH pH pH C M a M a M a M a M a M a a a Antiscalant rcher 84 RU...
Page 94: ......
Page 95: ......