background image

– 5

Special accessories

2.997-100.0

Braided hose set

Flexible 1 1/4“ braided hose with hose clamp (30 - 40 mm) with 
wing screw for a connection without tools.
Especially recommendable for the immersion pumps when remov-
ing large water quantities.
Max. operating pressure: 5 bar

2.997-201.0

Prefilter for immersion pump, 
small

The robust prefilter is easy to attach and protects your immersion 
pump, which increases the functional reliability.

6.997-359.0

Pump connection G1 (33.3 
mm) incl. Check valve

For pumps with G1 (33.3 mm) connection thread and 3/4" as well 
as 1" hoses, including union nut, hose clamp, flat packing and 
check valve.

6.997-347.0

Spiral hose, by the meter, 25 m, 
3/4"

By the meter for cutting hoses to individual lengths.

6.997-346.0

Spiral hose, by the meter, 25 m, 
1"

By the meter for cutting hoses to individual lengths.

2.645-142.0

Hose PrimoFlex, 25 m, 3/4"

Phthalate-free 3/4" garden hose for draining away the water.

2.645-247.0

Hose PrimoFlex, 50 m, 1"

Phthalate-free 1" garden hose for draining away the water.

Troubleshooting

DANGER

Risk of mortal danger on account of electric shock!
To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorised customer service 
personnel. 

Fault

Cause

Remedy

Pump runs but does not transport

Air in the pump

Unplug and plug in the mains plug of 
the pump repeatedly until the fluid is 
drawn

Suction area blocked

Pull out the mains plug and clean the 
suction area

(only in manual mode) Water level 
below the minimum water level

Immerse, whenever possible, the 
pump deeper into the feed fluid or 
proceed as described in Chapter Op-
eration.

Pump does not run or suddenly 
comes to a standstill during opera-
tions

Power supply interrupted

Check fuses and electrical connec-
tions

Thermal protection switch has 
switched off the pump due to over-
heating

Pull out the mains plug, let the pump 
cool down, clean the suction area, 
prevent dry running

Dirt particles have got jammed into 
the suction area

Pull out the mains plug and clean the 
suction area

The float switch stops the pump

Check position of float switch.

Pumping capacity is reducing

Suction area blocked

Pull out the mains plug and clean the 
suction area

Pumping capacity too low

The pumping capacity depends on 
the flow height, hose diameter and 
hose length.

Observe the maximum delivery 
height, see technical data. If neces-
sary, use a larger hose diameter or a 
shorter hose length.

Quick-Connect cannot be opened or 
closed.

Soiling in the plug system.

Remove and clean clip.

22

EN

Summary of Contents for SP 2 Flat

Page 1: ...SP 2 Flat SP 3 Dirt 59672880 05 16 Portugu s do Brasil 5 Espa ol 12 English 18 Fran ais 24...

Page 2: ...2...

Page 3: ...3...

Page 4: ...4...

Page 5: ...oque el trico Durante o bombeamento do l quido n o tocar no cabo fixo na al a de transporte nem nos ob jetos que est o em contato com o l quido bombeado por exem plo tubula es que se projetam na gua g...

Page 6: ...ua de piscinas lagos de jardins e fontes as bombas de imers o devem ser opera das apenas por um disjuntor para corrente de defeito com uma corrente de defeito no minal de no m x 30mA Se houver pessoas...

Page 7: ...gura Para a retirada do bocal de conex o pressionar o Quick Connect bot o cinza Figura Empurrar a abra adeira de mangueira sobre a mangueira Ao utilizar uma mangueira de ou 1 Aparafusar a pe a de cone...

Page 8: ...r desgaste portanto n o deixar que a bomba fun cione manualmente sem supervis o Em caso de fun cionamento a seco desativar imediatamente AVISO As sujeiras podem acumular se e ocasionar danos ao funcio...

Page 9: ...s e a montagem de pe as de reposi o s podem ser realizadas pelo servi o de assis t ncia autorizado Avaria Causa Elimina o da avaria A bomba funciona mas n o bombeia Ar na bomba Desconectar e conectar...

Page 10: ...5 6 6 Profundidade m x de mergulho m 6 5 7 7 Granula o m x da part cula de su jeira que pode ser bombeada mm 5 20 20 Altura m nima do l quido modo ma nual mm 7 60 60 Altura de l quido residual mm 1 2...

Page 11: ...es para Limpadoras e Secadores de Piso e Varredeiras Desgaste natural de filtros membranas areia carv o ativado mangueiras tubula es veda es para equipamentos deTratamento de gua Desgaste natural de m...

Page 12: ...al por descarga el ctrica Durante el funcionamiento de l quido de transporte no tocar la cuerda ni los objetos sujetos al asa de transporte que est n en contacto con el l quido de trans porte p ej tub...

Page 13: ...n y fuentes las bombas de in mersi n s lo se pueden utili zar con un interruptor de corriente de defecto con una corriente de defecto nominal de m x 30mA Si hay perso nas en la piscina o en el es tanq...

Page 14: ...onnect Los manguitos de conexi n vienen con el equipo sin montar Figura Presionar Quick Connect tecla gris para quitar el manguito de conexi n Figura Desplazar la brida de manguera sobre la mangue ra...

Page 15: ...au menta el desgaste no deje de vigilar la bomba si est en modo manual Desconectar inmediatamente en caso de marcha en seco AVISO La suciedad se puede acumular y provocar problemas en el funcionamient...

Page 16: ...sto sean realizados nica mente por el servicio t cnico autorizado Aver a Causa Modo de subsanarla La bomba funciona pero no transpor ta nada Aire en la bomba Enchufar y desenchufar la bomba va rias ve...

Page 17: ...ransporte m x m 5 6 6 Profundidad m x de inmersi n m 6 5 7 7 Tama o m ximo de grano de las par t culas de suciedad a transportar mm 5 20 20 Altura de l quidos m nima modo ma nual mm 7 60 60 Altura de...

Page 18: ...ic shock Do not touch feed fluids the rope attached to the carrying handle as well as objects that are in contact with the feed fluid e g pipelines extending into the water railings etc DANGER Risk of...

Page 19: ...te the pump if there are persons located in the swimming pool or the garden pond For safety reasons we rec ommend that you operate the appliance only via a earth leakage circuit breaker max 30 mA In A...

Page 20: ...ustration Slide the hose clamp onto the hose If a or 1 hose is used Screw pump connecting piece see special acces sory onto the connection nozzle Slide the hose onto the pump connecting piece and secu...

Page 21: ...leave the pump unattended during manual oper ation Switch off immediately in case of dry running NOTICE Soiling can deposit and lead to malfunctions Pump clear water or thoroughly rinse the pump af t...

Page 22: ...be carried out by the authorised customer service personnel Fault Cause Remedy Pump runs but does not transport Air in the pump Unplug and plug in the mains plug of the pump repeatedly until the flui...

Page 23: ...flow height m 5 6 6 Max immersion depth m 6 5 7 7 Max grain size of the dirt particles that can be transported mm 5 20 20 Minimum fluid height manual mode mm 7 60 60 Residual fluid height mm 1 25 25 W...

Page 24: ...e mort par choc lectrique Pendant l exploitation du fluide transport ne pas toucher la corde fix e sur la poign e de transport ni les objets qui sont en contact avec le fluide trans port par ex condui...

Page 25: ...0mA pour le pompage de vidage Si des personnes se trouvent dans les piscines ou l tang de jardin la pompe ne doit pas tre utilis e Pour des raisons de s curit nous recommandons fonda mentalement que l...

Page 26: ...e ma ni re non mont e Illustration Pour retirer la tubulure le raccord enfoncer le Quick Connect touche grise Illustration Pousser le collier de flexible sur le flexible Pour une utilisation d un flex...

Page 27: ...e pas laisser la pompe en fonctionnement manuel sans surveillance Mettre imm diatement hors tension en cas de marche sec REMARQUE Les salissures peuvent se d poser et provoquer des d fauts de fonction...

Page 28: ...de La pompe tourne mais ne d bite pas Air dans la pompe Brancher et d brancher la fiche sec teur de la pompe plusieurs reprises jusqu ce que le fluide soit aspir Zone d Aspiration bouch e D brancher l...

Page 29: ...ue max m 5 6 6 Profondeur d immersion max m 6 5 7 7 Granulom trie max des particules d impuret s transportables mm 5 20 20 Hauteur de liquide minimale mode manuel mm 7 60 60 Hauteur de liquide r sidue...

Page 30: ......

Page 31: ......

Page 32: ...http www kaercher com dealersearch...

Reviews: