background image

– 6

Figure A1

The sensor surface must have contact 
with the soil. For this purpose, the sen-
sor is inserted in the loose ground like a 
plant and the soil is pressed around it.

Do not step or hammer on the sensor.

Figure A2

Implant the sensor directly in the irriga-
tion area and ensure that the sensor is 
not located in a sink or elevation.

Figure 2, 4, B
Recommendation:

 Replace the batter-

ies of the control unit and the sensor as 
well as the sensor pad annually. 

Completely drain all water from the irri-
gation device.

Remove the batteries from the sensor 
and the control unit.

Store the irrigation device at a dry and 
frost-proof location.

Subject to technical modifications!

Implanting the sensor

Care and maintenance

Maintenance

Storage

Technical specifications

Operating pressure

0,1 - 1,0 (1 
- 10)

MPa 
(bar)

Max. feed temperature 35

°C

Ambient temperature

+5 -> +60 °C

Frequency

868,1

MHz

Radio range (max.)

100

m

Battery type

9V (6LR61 /
 Alkaline)

16

EN

Summary of Contents for SensoTimer ST6 Duo eco!ogic

Page 1: ...1 SensoTimer ST6 eco ogic SensoTimer ST6 Duo eco ogic 59665320 08 18 Deutsch 4 English 11 Fran ais 18 Italiano 25 Nederlands 32 Espa ol 39 Portugu s 46 Dansk 53 Norsk 60 Svenska 67 Suomi 74 81 Magyar...

Page 2: ...1 2 sensor eco ON OFF Ok esc menu 24 d min 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2...

Page 3: ...A C B D D E E F G F H I J K M L N O O P P Q D E B A 3...

Page 4: ...the ingredients at www kaercher com REACH At the end of the operating instructions you will find a selected list of spare parts that are often required You can procure the spare parts and the at tach...

Page 5: ...tap Do not pull on the attached hose Do not install the irrigation device near heat sources max ambient tempera ture 60 C Caution Only use 9V batteries type 6LR61 Al kaline Do not use rechargeable bat...

Page 6: ...ss of the sensor is cancelled with the esc menu button during the 60 second countdown In this case the moisture tripping limit at the control unit can not be set Locked inactive The 60 second countdow...

Page 7: ...f the sen sor cap Figure 5 Contact radio signal As soon as the contact of the radio sig nal is established the symbol for the ra dio signal appears permanently It is now guided through the setup se qu...

Page 8: ...nd confirm your selection with the OK but ton The valves are opened closed by re peatedly pressing the arrow keys The esc button terminates the manual irrigation and switches back into the au tomatic...

Page 9: ...Replace the batter ies of the control unit and the sensor as well as the sensor pad annually Completely drain all water from the irri gation device Remove the batteries from the sensor and the control...

Page 10: ...Alkaline or clean contacts Radio signal battery symbol and moisture val ue of the sensor are not indicated No radio communication be tween the control unit and the sensor The device is in its failure...

Reviews: