Note: 

The predefined order during com-

missioning must be strictly observed. Oth-
erwise it is not guaranteed that the sensor 
is correctly registered with the control unit. 
Assistance for the operating procedure is 
provided by the accompanying quick start.

Note: 

The battery is not included in the 

scope of delivery.

Figure 1, 2

Insert the battery into the battery com-
partment in the correct position (+/- 
marking).
As soon as the battery is inserted, the 
display, after a short self-test, changes 
directly into the settings mode for the 
current time. The hours of the time dis-
play are flashing. 

Figure 3

Set hours.

Press the 

OK button

 and set minutes.

Confirm the setting of the minutes by 
pressing the 

OK button

.

Note:

 From now on, the receiver waits for 

the radio signal of the sensor for teaching. 
During this time, the radio signal is flashing 
and the seconds countdown is counted 
down.

Important:

 In order to establish the radio 

contact between the receiver and the sen-
sor, the sensor battery must be inserted 
within 60 seconds. 

CAUTION

The moisture absorption of the sensor pad 
can be impaired by grease or oil on the sur-
face. Do not touch or wipe the sensor pad 
with greasy/oily hands/rags.

Figure 4

Remove the sensor cap of the sensor.

Connect the battery with the battery 
clip. The connected battery is reinsert-
ed in the casing with the battery clip go-
ing in first.

Close the sensor by means of the sen-
sor cap.

Figure 5

Contact radio signal.
As soon as the contact of the radio sig-
nal is established, the symbol for the ra-
dio signal appears permanently. It is 
now guided through the setup se-
quence (preset value for moisture, 
times, etc.).

Figure 6

Sensor 1 was detected successfully.

Note: 

The operating mode is specified and 

saved during the teaching process. A 
change of the operating mode (e.g. from 
sensor control to time control) is only possi-
ble by a new teaching process after a reset.

Figure 7

Set the tripping limit for the soil moisture.

Note:

 Setting is only possible in the sen-

sor-controlled operation, not in the time-
controlled operation. 
Drops show the measured soil moisture, 
the adjustable triangles show the tripping 
limit. As soon as the measured soil mois-
ture falls below the tripping limit, the irri-
gation starts automatically at the next set 
time.

Figure 8.1, 8.2

Set the irrigation time for mornings and 
evenings.
Per day 2 times can be set at which the 
irrigation starts if the measured soil mois-
ture is below the tripping limit. With 

"- -:- 

-"

 the irrigation time can be deactivated.

Figure 9

Set the irrigation duration.
The irrigation duration per irrigation cycle 
can be set between 1 - 90 minutes. With 

"- -"

 the irrigation duration is deactivated.

Figure 10

Set the irrigation delay.
The irrigation can be delayed for 1 - 7 
days; this stimulates the root develop-
ment of the plants. Moreover, it saves 
water if it rains during the delay days. 
With setting

"- d"

 this function is deactivated.

Preparation control unit 

Preparation / teaching sensor 1 

Irrigation settings of water outlet 1

14

EN

Summary of Contents for SensoTimer ST6 Duo eco!ogic

Page 1: ...1 SensoTimer ST6 eco ogic SensoTimer ST6 Duo eco ogic 59665320 08 18 Deutsch 4 English 11 Fran ais 18 Italiano 25 Nederlands 32 Espa ol 39 Portugu s 46 Dansk 53 Norsk 60 Svenska 67 Suomi 74 81 Magyar...

Page 2: ...1 2 sensor eco ON OFF Ok esc menu 24 d min 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2...

Page 3: ...A C B D D E E F G F H I J K M L N O O P P Q D E B A 3...

Page 4: ...the ingredients at www kaercher com REACH At the end of the operating instructions you will find a selected list of spare parts that are often required You can procure the spare parts and the at tach...

Page 5: ...tap Do not pull on the attached hose Do not install the irrigation device near heat sources max ambient tempera ture 60 C Caution Only use 9V batteries type 6LR61 Al kaline Do not use rechargeable bat...

Page 6: ...ss of the sensor is cancelled with the esc menu button during the 60 second countdown In this case the moisture tripping limit at the control unit can not be set Locked inactive The 60 second countdow...

Page 7: ...f the sen sor cap Figure 5 Contact radio signal As soon as the contact of the radio sig nal is established the symbol for the ra dio signal appears permanently It is now guided through the setup se qu...

Page 8: ...nd confirm your selection with the OK but ton The valves are opened closed by re peatedly pressing the arrow keys The esc button terminates the manual irrigation and switches back into the au tomatic...

Page 9: ...Replace the batter ies of the control unit and the sensor as well as the sensor pad annually Completely drain all water from the irri gation device Remove the batteries from the sensor and the control...

Page 10: ...Alkaline or clean contacts Radio signal battery symbol and moisture val ue of the sensor are not indicated No radio communication be tween the control unit and the sensor The device is in its failure...

Reviews: