INSTALLATION

Place machine in a convenient location providing 
ample support, drainage and room for maintenance.
These machines are designed for indoor use. 

They must be stored indoors when not in use.

Location:

The location should protect the machine from dam-
aging environmental conditions, such as wind, rain, 
and freezing temperatures.
The machine should be run on a level surface where 
it is not readily influenced by outside sources such 
as strong winds, freezing temperatures, rain, etc. 
The machine should be located to allow accessibil-
ity for refilling of fuel, adjustments and maintenance. 
Normal precautions should be taken by the opera-
tor of the machine to prevent excess moisture from 
reaching the power unit or electrical controls.
It is recommended that a partition be made between  
the wash area and the machine to prevent direct wa-
ter spray from coming in contact with the machine. 
Excess moisture reaching any electrical components 
or controls will reduce machine life and may cause 
electrical shorts.
During installation of the machine, beware of poorly 
ventilated locations or areas where exhaust fans 
may cause an insufficient supply of oxygen. Suffi-
cient combustion can only be obtained when there is 
a sufficient supply of oxygen available for the amount 
of fuel being burned. If it is necessary to install a 
machine in a poorly ventilated area, outside fresh 
air may have to be piped to the burner and a fan 
installed bringing the air into the machine.
WARNING: Avoid small areas or areas near exhaust 
fans.

Electrical

The machine, when installed, must be electrically 
grounded in accordance to local codes. Check for 
proper power supply using a volt meter. The  
HOT 2-1100, HOT 2-1500, and HOT 3-1100 each 
require a 120V-20 amp receptacle to comply to the 
UL 1776 Standard.

Placement

Do not locate near any combustible material.  
Keep all flammable material at least 20 feet away.
Allow enough space for servicing the machine.
Local code will require certain distances from floor 
and walls. (Two feet away should  be adequate.)

Water Source

Water source for machine should be supplied by a  
5/8" I.D. garden hose with a city water pressure 
of not less than 30 psi. If the water supply is inad-
equate, or if the garden hose is kinked, the machine 
will run very rough and the burner will not fire.

Connection

Connect the wand, nozzle, hose and spray gun, 
where applicable (see Component Identification).  
On pipe thread connections, use teflon tape to  
avoid water leaks. 

Venting

Adding exhaust vent pipe to your oil fired burner is 
not recommended.  The pipe restricts air flow which 
causes carbon buildup, which affects the operation, 
and increases maintenance on the coil. If a stack 
must be used, refrain from using 90° bends. If the 
pipe cannot go straight up then use only 45° bends 
and go to the next larger size pipe. The overall pipe 
length must not exceed 6 feet. The addition of a vent 
pipe will require an air adjustment and smoke test.

IMPORTANT SAFETY INFORMATION

Follow the maintenance instructions 
specified in the manual. 

Summary of Contents for Landa HOT 2-1100

Page 1: ...8 917 208 0 OPERATOR S MANUAL For technical assistance or the Landa Dealer nearest you consult our web page at www landa com HOT HOT 2 1100 HOT2 1500 HOT 4 2000 HOT 3 1100 HOT 3 300 89172080 1 ...

Page 2: ......

Page 3: ...ould record both serial number and date of purchase and keep in a safe place for future reference 8 917 208 0 HOT Rev 05 17 Introduction Important Safety Information 4 5 7 Component Identification 6 Installation 7 Assembly Instructions 8 Operating Instructions 9 Detergents General Cleaning Techniques 10 Shutting Down Clean up 11 Storage 11 Maintenance Service 12 14 Preventative Maintenance and Oil...

Page 4: ...a ground fault circuit interrupter GFCI If rated more than 250 volts or more than single phase this product should only be connected to a power supply receptacle protected by a GFCI DANGER Improper connection of the equipment grounding conductor can result in a risk of elec trocution Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly gr...

Page 5: ...bility of a fall due to slippery surfaces 20 Do not overreach or stand on unstable support Keep good footing and balance at all times 21 Do not operate this machine when fatigued or under the influence of alcohol prescription medications or drugs IMPORTANT SAFETY INFORMATION WARNING USE PROTECTIVE EYE WEAR AND CLOTHING WHEN OPERATING THIS EQUIPMENT WARNING High pressure spray can cause paint chips...

Page 6: ...tional 8 903 430 0 High Pressure Nozzle Detergent Pick up Tube Quick Coupler Power Supply GFCI Steam Nozzle Steam Wand 3 300 Spray Gun Trigger Variable Pressure Control Handle Variable Pressure Wand 2 11024D 2 15024D 3 11024D 4 2000 2 11026D 2 15026D Pump Switch High Pressure Hose Water Supply Hose not included Safety Latch Detergent Bucket not included Brass Soap Nozzle Brake Burner Switch Strain...

Page 7: ...ir may have to be piped to the burner and a fan installed bringing the air into the machine WARNING Avoid small areas or areas near exhaust fans Electrical The machine when installed must be electrically grounded in accordance to local codes Check for proper power supply using a volt meter The HOT 2 1100 HOT 2 1500 and HOT 3 1100 each require a 120V 20 amp receptacle to comply to the UL 1776 Stand...

Page 8: ...reads Move safety latch into locked position STEP 6 Check oil level by using supplied dip stick Use SAE 30W non detergent only STEP 7 Fill fuel tank with proper fuel 89172080 9 STEP 5 Release the coupler collar and push the nozzle until the collar clicks Pull the nozzle to make sure it is seated properly 89172080 3 89172080 4 Detergent Injector STEP 4 Pull the spring loaded collar of the wand coup...

Page 9: ...the vari able pressure control handle coun terclockwise to reduce pressure 89172080 13 Selection of high or low pressure is accompanied by turning the handle Note High pressure nozzle must be inserted at end of wand to obtain high pressure To apply soap read detergent instructions Variable Pressure Control Handle Trigger Variable Pressure Wand VP High Pressure Nozzle Brass Soap Nozzle 89172080 10 ...

Page 10: ...cleaning solu tion and apply to surface at low pressure for best results limit your work area to sections approxi mately 6 feet square and always apply detergent from bottom to top Allow detergent to remain on surface 1 3 minutes Do not allow detergent to dry on surface If surface appears to be drying simply wet down surface with fresh water If needed use brush to remove stubborn dirt Rinse at hig...

Page 11: ...tion This closes both the intake and exhaust valves to prevent rusting of cylinder 4 Cover the pressure washer and store in a clean dry place that is well ventilated away from open flame or sparks NOTE The use of a fuel additive such as STA BIL or an equivalent will minimize the formulation of fuel deposits during shortage Such additives may be added to the gasoline in the fuel tank of the engine ...

Page 12: ...nty Winterizing Procedure Damage due to freezing is not covered by warranty Adhere to the following cold weather procedures whenever the washer must be stored or operated outdoors under freezing conditions During winter months when temperatures drop below 32 F protecting your machine against freezing is necessary Store the machine in a heated room If this is not possible then mix a 50 50 solution ...

Page 13: ... 5 32 Gap Electrode Nozzle off blade Lay blade across one contact OK if arc will span 1 2 between end of blade and other contact see illustration below Transformer Check Burner Nozzle Keep the tip free of surface deposits by wiping it with a clean solvent saturated cloth being careful not to plug or enlarge the nozzle For maximum efficiency replace the nozzle each season Fuel Control System These ...

Page 14: ...r and the air band should be moved to allow the air to flow through the burner Sharp eye burning white fumes indicate too much air flow ing through the combustion chamber The air band should be moved to allow less air to flow through the burner To adjust Loosen locking screw found on the air band Start machine and turn burner ON and close air band until black smoke appears from burner exhaust vent...

Page 15: ...t enough to cause the flame tips to appear absolutely clean Removal of Soot and Heating Coil In the heating process fuel residue in the form of soot deposits may develop between the heating coil pipe and block air flow which will affect burner combustion When soot has been detected on visual observation the soot on the coil must be washed off Follow these steps to remove the coil 1 Disconnect hose...

Page 16: ...zzle Every 6 months Replace Quick Connects Annually Clean Water and Detergent Screen Filter Weekly Replace HP Hose If there is any sign of wear Grease Motor Every 10 000 hours Check Burner Nozzles Annually Unloader Valve Annually This pressure washer was produced with the best available materials and quality craftsmanship However you as the owner have certain responsibilities for the correct care ...

Page 17: ...e Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for proper size or obstruc tion DETERGENT NOT DRAWING Air leak Tighten all clamps Check detergent lines for holes Valve in the injector head may be blocked dirty or damaged Clean or replace valve in injector Filter screen on detergent suction hose plugged Clean or replace Dried up detergent plugging meter...

Page 18: ...ter pressure Do not close trigger on spray gun for longer than 1 2 minutes OIL DRIPPINGS Oil seal worn Check and replace if necessary MACHINE SMOKES Improper fuel or water in fuel Drain tank and replace contaminated fuel Improper air adjustment Readjust air bands on burner assembly Low fuel pressure Adjust fuel pump pressure to specifications Weak fuel pump Check fuel pump pressure Replace pump if...

Page 19: ...achines with spray gun control for proper on off fuel flow control Clogged burner nozzle Replace Water not turned on Turn on water to activate burner flow switch Fuel solenoid malfunction Remove test for continuity and replace as needed Fuel solenoid malfunction Replace if needed Pressure switch malfunction Test for proper operation Replace if needed PUMP MOTOR STOPS AFTER A FEW MINUTES OF OPERATI...