Illustrations on Page 3

Park the appliance on an even surface.

Illustration 

Put the high-pressure hose through the hose guide 
from the back.

Illustration 

Push the high pressure hose into the trigger gun 
until it locks audibly.

Note:

 Make sure the connection nipple is aligned 

correctly.
Check the secure connection by pulling on the high 
pressure hose.

Unwind the high pressure hose from the hose 
drum.

Insert the mains plug into the socket. 

For connection values, see type plate/technical data.

ATTENTION

Impurities in the water can damage the high-pressure 
pump and the accessories. For protection, the use of 
the KÄRCHER water filter (optional accessory, order 
no. 4.730-059) is recommended.

Observe regulations of water supplier.

ATTENTION

Hose couplings made of metal with aquastop can dam-
age the pump! Please use plastic couplings or KÄRCH-
ER brass couplings.

Illustration 

Screw the coupling element to the water connec-
tion on the appliance.

Attach the water supply hose to the coupling on the 
water connection.

Connect the water supply hose to the water supply.

Completely open the water tap.

This high-pressure cleaner is suited to work with the 
KÄRCHER suction hose with backflow valve (Optional 
accessory, order no. 2.643-100) to draw in surface wa-
ter, e.g. from water butts or ponds (see specifications for 
max. suction height). 

Note:

 With vacuuming operation, the coupling for the 

water connection is not required.

Fill the suction hose with water.

Screw the suction hose into the water connection of 
the appliance and insert it into the water source 
(e.g. rainwater drum).

Bleed the device as follows prior to operation:

Turn on the appliance “I/ON”.

Unlock the lever of the trigger gun.

Push the lever of the trigger gun, the device will 
switch on.

Let the device run (max. 2 minutes) until the water 
exits the trigger gun without bubbles.

Release the lever of the trigger gun.

Lock the lever of the trigger gun.

ATTENTION

Dry running of more than 2 minutes leads to damage of 
the high-pressure pump. If the appliance does not build 
up pressure within 2 minutes, switch the appliance off 
and proceed in accordance with the instructions in 
Chapter "Troubleshooting".

CAUTION

Keep a distance of at least 30 cm when using the jet for 
cleaning painted surfaces to avoid damage.

ATTENTION

Car tyres, paint or sensitive surfaces such as wood 
should not be cleaned with the dirt blaster, as there is a 
risk of damage.

Select a spray lance suitable for the cleaning task.

Illustration 

Push the spray lance into the trigger gun and fasten 
it by a 90° rotation.

Turn on the appliance “I/ON”.

Unlock the lever of the trigger gun.

Push the lever of the trigger gun, the device will 
switch on.

Note:

 Release the lever of the trigger gun; the de-

vice will switch off again. High pressure remains in 
the system.

Full Control spray lance Vario Power 

Turn the spray lance until the LED of the required 
pressure level is on at the pressure indicator of the 
trigger gun.

The pressure indicator on the trigger gun shows the cur-
rently set pressure level during operation with a Full 
Control spray lance.

Note:

 The pressure indicator is not significant during 

operation with the T-Racer and other accessories.

ATTENTION

The sensitivity of the materials can strongly differ de-
pending on the age and the condition. The so-called 
recommendations are non-binding.

Start up

Water supply

Water supply from mains

Drawing in water from open reservoirs

Operation

High pressure operation

Full Control System

Pressure level

For example, recommended for 

HARD

Stone terraces made of paving 
stones or exposed aggregate con-
crete, asphalt, metal surfaces, gar-
den utensils (wheelbarrow, spade, 
etc.)

MEDIUM

Motorcar / motorcycle, brick sur-
faces, plastered walls, plastic furni-
ture

SOFT

Wooden surfaces, bicycles, sand 
stone surfaces, rattan furniture

MIX

Operation with detergent

Summary of Contents for K 7 Premium Full Control

Page 1: ...K 7 Premium Full Control Operating Instructions Please read the operating instructions carefully before using the unit 59658110 12 15...

Page 2: ...2...

Page 3: ...3...

Page 4: ...leads to severe injuries or death WARNING Pointer to a possibly dangerous situation which can lead to se vere injuries or death CAUTION Pointer to a possibly dangerous situation which can lead to mi...

Page 5: ...intenance works Repair work and work on the electrical components may only be performed by an au thorised customer service WARNING The appliance may only be connected to an electric sup ply that has b...

Page 6: ...ated by children or per sons who have not been in structed accordingly This appliance is not intended for use by persons with limit ed physical sensory or men tal capacities or lacking expe rience and...

Page 7: ...Type BA Water that has flown through a system separator is no longer classified as drinking water High pressure hoses fixtures and couplings are important for the safety of the appli ance Only use hig...

Page 8: ...sure cleaners aerosols can develop Inhaling aerosols can cause health damage Depending on the applica tion completely shielded noz zles e g surface cleaner that significantly reduce the emission of a...

Page 9: ...ansport damage please contact your dealer Fabric reinforced water hose with commercially available coupling Minimum diameter 1 2 inches 13 mm Minimum length 7 5 m Use this pressure washer for private...

Page 10: ...trigger gun without bubbles Release the lever of the trigger gun Lock the lever of the trigger gun ATTENTION Dry running of more than 2 minutes leads to damage of the high pressure pump If the applian...

Page 11: ...jury or damage Mind the weight of the appliance during transport Lift appliance by the carrying handle and carry it Pull out the transport handle until it audibly snaps into place Pull the appliance b...

Page 12: ...vice checked by the customer service Voltage reduction due to weak mains supply or when using an extension cable Upon switch on push the lever of the trigger gun first and then switch the power switch...

Page 13: ...ecifications Electrical connection Voltage 220 240 1 50 V Hz Connected load 2 8 kW Protection class IP X5 Protective class I Mains fuse slow blow 13 A Water connection Max feed pressure 0 6 MPa Max fe...

Page 14: ...14 English Use only original K RCHER spare parts Spare Parts...

Page 15: ...cher com dealersearch 220 240 1 50 V Hz 2 8 kW IP X5 I 13 A 0 6 MPa 60 C 12 l min 0 5 m 15 MPa 16 MPa 9 2 l min 10 l min 0 3 l min 27 N 463 mm 330 mm 667 mm 20 1 kg EN 60335 2 79 K 5 3 1 0 m s2 m s2 L...

Page 16: ...I ON 0 OFF AAA 0 OFF I ON...

Page 17: ...Plug n Clean Vario Power MIX MIX Plug n Clean 5 0 OFF 0 OFF Plug n Clean Vario Power...

Page 18: ...K RCHER 2643100 I ON 30 90 I ON Vario Power T K RCHER Plug n Clean Plug n Clean HARD MEDIUM SOFT MIX...

Page 19: ...1 2 13 7 5 KARCHER REACH www kaercher com REACH 3 3 KARCHER 059 4 730 K RCHER...

Page 20: ...FFP 2 2 1 2 3 4 5 6 7 Plug n Clean 8 9 10 11 12 13 14 15 16 17 18 19 20 21 MIX 1 SOFT 2 MEDIUM 3 HARD 22 23 24 25 Vario Power 26 27 Plug n Clean 28 KARCHER...

Page 21: ...30 EN 12729 Typ BA...

Page 22: ...60 IEC 60364 I 30 1 10 m 1 5 mm2 10 30 m 2 5 mm2...

Page 23: ......

Page 24: ...K 7 Premium Full Control 59658110 12 15...

Reviews: