Illustrations on Page 15

Mount loose parts delivered with appliance prior to start-
up.

Illustration 

Hook the net into the hooks shown in the illustra-
tion.

Before 

initial

 startup, the high-pressure 

gun must be coupled to the high-pressure 
cleaner. 

Insert the mains plug into the socket. 

Immediately thereafter, simultaneously 
press the + and - buttons on the high-
pressure gun.

Hold down the buttons until the entire 
signal strength symbol flashes.
Once coupling is complete, all six pressure levels 
will be displayed.

Park the appliance on an even surface.

Illustration 

Put the high-pressure hose through the hose guide 
from the back.

Illustration 

Push the high pressure hose into the trigger gun 
until it locks audibly.

Note:

 Make sure the connection nipple is aligned 

correctly.
Check the secure connection by pulling on the high 
pressure hose.

Unwind the high pressure hose from the hose 
drum.

Insert the mains plug into the socket. 

For connection values, see type plate/technical data.

ATTENTION

Impurities in the water can damage the high-pressure 
pump and the accessories. For protection, the use of 
the KÄRCHER water filter (optional accessory, order 
no. 4.730-059) is recommended.

Observe regulations of water supplier.

ATTENTION

Hose couplings made of metal with aquastop can dam-
age the pump! Please use plastic couplings or KÄRCH-
ER brass couplings.

Illustration 

Screw the coupling element to the water connec-
tion on the appliance.

Attach the water supply hose to the coupling on the 
water connection.

Connect the water supply hose to the water supply.

Completely open the water tap.

This high-pressure cleaner is suited to work with the 
KÄRCHER suction hose with backflow valve (Optional 
accessory, order no. 2.643-100) to draw in surface wa-
ter, e.g. from water butts or ponds (see specifications for 
max. suction height). 

Note:

 With vacuuming operation, the coupling for the 

water connection is not required.

Fill the suction hose with water.

Screw the suction hose into the water connection of 
the appliance and insert it into the water source 
(e.g. rainwater drum).

Bleed the device as follows prior to operation:

Turn on the appliance “I/ON”.

Unlock the lever of the trigger gun.

Push the lever of the trigger gun, the device will 
switch on.

Using the +/- buttons, set the high-pressure gun to 
detergent level 1.

Let the device run (max. 2 minutes) until the water 
exits the trigger gun without bubbles.

Release the lever of the trigger gun.

Lock the lever of the trigger gun.

Assembly

Attach the net to the accessory compartment

Coupling of the high-pressure gun

Start up

Water supply

Water supply from mains

Drawing in water from open reservoirs

Summary of Contents for K 7 Premium Full Control Plus

Page 1: ...English K 7 Premium Full Control Plus Operating Instructions Please read the operating instructions carefully before using the unit 59668700 10 16...

Page 2: ...roper use 9 Environmental protection 9 Assembly 10 Start up 10 Operation 11 Transport 12 Storage 12 Care and maintenance 12 Troubleshooting 13 Accessories and Spare Parts 13 Helpline 13 Warranty 14 Te...

Page 3: ...plug and the socket with wet hands Check the power cord with mains plug for damage prior to every use Immediately have damaged power cord replaced by an authorised customer service electrician Do not...

Page 4: ...um DANGER The user must use the appli ance as intended The person must consider the local condi tions and must pay attention to other persons in the vicinity when working with the appli ance Check imp...

Page 5: ...ity for the appli ance prior to any work on or with the appliance to prevent accidents or damage The water jet that is emitted from the high pressure nozzle results in a repulsion power acting on the...

Page 6: ...arator Ensure that the connection of your building water installation on which the high pressure cleaner is operated is equipped with a system separator pursuant to EN 12729 Type BA Water that has flo...

Page 7: ...cleaners aerosols can develop Inhaling aerosols can cause health damage Depending on the applica tion completely shielded noz zles e g surface cleaner that significantly reduce the emission of aqueous...

Page 8: ...8 English Description of the Appliance...

Page 9: ...rraces gardening tools etc by means of a high pressure water jet if necessary with ad ditional cleaning agents with accessories replacement parts and cleaning agents approved by K RCHER Please observe...

Page 10: ...plier ATTENTION Hose couplings made of metal with aquastop can dam age the pump Please use plastic couplings or K RCH ER brass couplings Illustration Screw the coupling element to the water connec tio...

Page 11: ...use in a Plug n Clean detergent bottle DANGER When using detergents the material data safety sheet issued by the detergent manufacturer must be adhered to especially the instructions regarding persona...

Page 12: ...Risk of personal injury or damage Observe the rotation direction of the hose reel upon coil ing up the high pressure hose Coil up the high pressure hose Turn the hose reel in a counter clockwise dire...

Page 13: ...lug n Clean detergent bottle is placed into the detergent connection facing down Check replace the batteries Decrease the distance between high pressure gun and high pressure cleaner Couple it to the...

Page 14: ...ltage 220 240 1 50 V Hz Connected load 2 8 kW Protection class IP X5 Protective class I Mains fuse slow blow 13 A Water connection Max feed pressure 0 6 MPa Max feed temperature 60 C Min feed volume 1...

Page 15: ...English 15 Illustration...

Page 16: ...13...

Page 17: ...12...

Page 18: ...com dealersearch 220 240 1 50 V Hz 2 8 kW IP X5 I 13 A 0 6 MPa 60 C 12 l min 0 5 m 15 MPa 18 MPa 9 2 l min 9 2 l min 0 3 l min 27 N 463 mm 330 mm 667 mm 20 3 kg EN 60335 2 79 K 1 3 0 6 m s2 m s2 LpA K...

Page 19: ...10 0 OFF I ON 3 1 MIX Plug n Clean 20...

Page 20: ...9 Plug n Clean 3 1 I ON 0 OFF AAA...

Page 21: ...8 30 3 1 90 I ON K RCHER Plug n Clean Plug n Clean Plug n Clean 3 1 MIX Plug n Clean 30 1 5 0 OFF 30 0 OFF...

Page 22: ...7 K RCHER K RCHER 2643100 I ON 1 3 1 T...

Page 23: ...6 KARCHER REACH www kaercher com REACH 13 6 KARCHER 059 4 730...

Page 24: ...5...

Page 25: ...4 FFP 2 1 2 3 4 5 6 7 Plug n Clean 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 LCD 23 24 4 25 26 1 SOFT 2 MEDIUM 3 HARD 2 27 1 2 3 28 29 30 31 3 1 3 32 3 33 3 2 34 1 2 35 Plug n Clean 36 1 2 13 7 5...

Page 26: ...3 30 EN 12729 Typ BA...

Page 27: ...2 60 IEC 60364 I 30 1 10 m 1 5 mm2 10 30 m 2 5 mm2...

Page 28: ...http www kaercher com dealersearch...