background image

Technical Data

Power connection
Voltage (1~60 Hz) ............................ 120 V
Amp draw ........................................... 13 Amps
Protection class .................................... 1
Power supply ...... Order-No.   6.647-508
Water connection
Supply temperature (max.) ................ 60 °C

(140 °F)

Supply rate (min.) ............................ 600 l/h

(2.5 gpm)

Supply pressure (max.) ..................... 12 bar

(170 psi)

Supply hose ...........................................
 - length (min.) ................................... 7,5 m

(25 ft)

 - diameter (min.) .............................. 1/2 in
Suction height from open tank at a
 water temperature of 20°C (68°F) ...... 1 m

(3 ft)

Performance data
Max. pressure ................................ 1500 psi
Flow rate ........................................... 450 l/h

(1.8 gpm)

Detergent intake ............................. 0–25 l/h

(0-7 gph)

Recoil force of hand-held spray gun
at operating pressure (max.) ............. 19 N
Sound pressure level (DIN 45635) ... 74 dB (A)
Dimensions
Length ............................................... 508 mm

(20 in)

Width ................................................ 255 mm

(10 in)

Height ............................................... 284 mm

(11,2 in)

Weight with accessories ................. 15,5 kg

(34 lbs)

Circuit Diagram

C1 Running capacitor
F1 Temperature  fuse
M1 Motor
S1 Appliance switch
S2 Pressure-operated switch

Données techniques

Branchement électrique
Tension(1~60 Hz) ............................ 120 V
Classe de protection ............................ II
Câbles d´alimentation ............................ n° de réf.6.647-508
Branchement de l’eau
Température d’arrivée d’eau (max.) . 60 °C

(140 °F)

Débit mini. d’arrivée d’eau (mini.) ... 600 l/h

(2.5 gpm)

Pression d´arrivée (maxi.) ................. 12 bars

(170 psi)

Flexible d’arrivée d’eau .........................
 - longueur (mini.) .............................. 7,5 m

(25 ft)

 - Diamètre (mini.) ............................. 1/2 in
Hauteur d’aspiration depuis un
réservoir ouvert, eau à 20°C(68°F) ..... 1 m

(3 ft)

Caractéristiques de puissance
Max.Pression .................................
Débit de refoulement ....................... 450 l/h
Débit d’aspiration de détergent ...... 0-25 l/h

(0-7 gph)

Force de recul au niveau de la poignée-
pistolet,à la pression de service ........ 19 N
Niveau de bruit (DIN 45635) ............. 74 dB (A)
Dimensions
Longueur .......................................... 508 mm

(20 in)

Largeur ............................................. 255 mm

(10 in)

Hauteur ............................................. 284 mm

(11,2 in)

Poids, accessoires compris ............ 15,5 kg

(34 lbs)

Schéma des circuits  électriques

C1 Condensateur de service
F1 Fusible thermique
M1 Moteur
S1 Commutateur de l’appareil
S2 Pressostat

Summary of Contents for K 502 MS plus

Page 1: ...5 959 960 02 01 502 MS plus...

Page 2: ...into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Improper connection of the equipment grounding conductor can result in a ri...

Page 3: ...ui est install e correctement et mise la terre en respectant les prescriptions et les codes locaux DANGER Le branchement incorrect du conducteur de mise la terre de l quipment peut provoquer un risque...

Page 4: ...EVE PRESSURE Water Supply Cold Water Only Water hose must be at least 3 4 inch in diameter Flow rate of water supply must not fall below 2 GPM gallons per minute Flow rate can be determined by running...

Page 5: ...AU NETTOYAGE OU D ENLEVER TOUTE PI CE Alimentation d eau Eau froide seulement Le boyau doit avoir un diam tre d au moins 2 cm Le d bit de l alimentation d eau ne doit pas tre inf rieur 7 5 lpm 2 GPM L...

Page 6: ...aspiration de d tergent bague de dosage 14Sortie haute pression 1 Appliance switch ON OFF 2 Water connection with filter 3 Quick coupler male 4 Quick coupler female 5 Spray gun with safety ratchet A...

Page 7: ...7...

Page 8: ...8 Starting Mise en service...

Page 9: ...9 Operation with high pressure Marche avec haute pression...

Page 10: ...10 1 Operation with Detergent 2 Suction operation 1 Marche avec un d tergent 2 Mode aspiration...

Page 11: ...11 1 Switching Off 2 Care and maintenance 1 Domaine d application 2 Entretien et maintenance...

Page 12: ...he connector cable for damage Appliance does not reach Pressure Set the spray lance to the maximum working pressure Vent the appliance Clean the strainer in the water connection Check the inlet water...

Page 13: ...nt pas la pression d sir e R gler la lance sur la pression de travail maximale Chasser les bulles d air pr sentes dans l appareil Nettoyerlecriblemont danslaprised eau V rifier le d bit d arriv e d ea...

Page 14: ...S1 Appliance switch S2 Pressure operated switch Donn es techniques Branchement lectrique Tension 1 60 Hz 120 V Classe de protection II C bles d alimentation n de r f 6 647 508 Branchement de l eau Tem...

Page 15: ......

Page 16: ...SERVICE CENTER 1 800 465 4980 CENTRE DE SERVICE...

Reviews: