background image

– 6

The scope of delivery of the device is illustrated on the 
packaging. Check the content for completeness upon 
unpacking.
In the event of missing accessories or any transport 
damage, please contact your dealer.

Fabric-reinforced water hose with commercially 
available coupling. 

Minimum diameter, 1/2 inches (13 mm).

Minimum length 7.5 m.

These operating instructions describe the maximum 
equipment. Depending on the model, there are differ-
ences in the scopes of delivery (see packaging).

See fold-out page 4 for illustrations

1

Coupling element for water connection

2

Water connection with integrated sieve

3

High pressure hose

4

Hose guide 

5

Storage for spray lances

6

Storage / parking position for trigger gun

7

Connection for Plug 'n' Clean detergent

8

Carrying handle

9

Transport handle, detachable

10 Hose switch
11 High pressure connection
12 Appliance switch "0/OFF“/ „I/ON“
13 Mains cable with mains plug
14 Accessory compartment
15 Hooks for fastening the net 
16 Net for accessory compartment
17 Bearing wheel
18 Base with carrying handle
19 Full Control trigger gun
20 Battery compartment
21 LED pressure indicator

MIX / 1 - SOFT / 2 - MEDIUM / 3 - HARD

22 Battery compartment lock
23 Lock trigger gun
24 Button for detaching the high-pressure hose from 

the trigger gun

25 Full Control spray lance dirt grinder

For strong contaminations
Pressure level: HARD

26 Full Control spray lance Vario Power 

Carrying out the most common cleaning tasks
Pressure levels: HARD / MEDIUM / SOFT / MIX

* Optional accessories

27 Plug 'n' Clean detergent bottle with locking lid

** not included in the scope of delivery

28 Water supply hose

Special accessories expand the possibilities of using 
your appliance. Please contact your KÄRCHER dealer 
for further information.

See fold-out page 3 for illustrations

Mount loose parts delivered with appliance pri-
or to start-up.
You will need the 2 included screws as well as a Philips 
screwdriver PH 2.

Illustration 

Insert base.

Insert the included dowels all the way into the 
holes.

Secure the base with the enclosed screws.

Illustration 

Hook in storage for spray lances.

Secure the storage for the spray lances by means 
of two screws.

Illustration 

Attach the transport handle.

Secure the transport handle by means of two 
screws.

Illustration 

Hook the net into the hooks shown in the illustra-
tion.

Illustration 

Push the high pressure hose into the trigger gun 
until it locks audibly.

Note:

 Make sure the connection nipple is aligned 

correctly.

Check the secure connection by pulling on the high 
pressure hose.

Scope of delivery

Additionally required

Description of the Appliance

Special accessories

Assembly

Installing the base

Install storage for spray lances

Install the transport handle

Attach the net to the accessory compartment

Connect the high pressure hose to the 

trigger gun

12

EN

Summary of Contents for K 5 Full Control

Page 1: ...an ais 17 Italiano 23 Nederlands 29 Espa ol 35 Portugu s 41 Dansk 47 Norsk 52 Svenska 57 Suomi 63 69 T rk e 75 81 Magyar 87 e tina 93 Sloven ina 99 Polski 105 Rom ne te 111 Sloven ina 117 Hrvatski 123...

Page 2: ...3 3...

Page 3: ...4 4...

Page 4: ...Wird der Hebel an der Hochdruckpistole losgelassen schaltet der Druckschalter die Pumpe ab der Hoch druckstrahl stoppt Wird der Hebel gezogen schaltet die Pumpe wieder ein Bei zu hoher Stromaufnahme...

Page 5: ...Dreckfr ser F r hartn ckige Verschmutzungen Druckstufe HARD 26 Full Control Strahlrohr Vario Power F r die g ngigsten Reinigungsaufgaben Druckstufen HARD MEDIUM SOFT MIX Optionales Zubeh r 27 Plug n...

Page 6: ...ls 2 Minuten f hrt zu Besch di gungen an der Hochdruckpumpe Baut das Ger t inner halb von 2 Minuten keinen Druck auf Ger t abschalten und gem Hinweisen im Kapitel Hilfe bei St rungen verfahren VORSICH...

Page 7: ...CHTUNG Beim Trennen von Zulauf oder Hochdruckschlauch kann nach dem Betrieb warmes Wasser aus den An schl ssen austreten Ger t von der Wasserversorgung trennen VORSICHT Verletzungs und Besch digungsge...

Page 8: ...n zuerst den Hebel der Hochdruck pistole dr cken dann den Ger teschalter auf I ON stellen Einstellung am Strahlrohr pr fen Wasserversorgung auf ausreichende F rdermen ge berpr fen Sieb im Wasseranschl...

Page 9: ...ugh he 0 5 m Leistungsdaten Arbeitsdruck 12 5 MPa Max zul ssiger Druck 14 5 MPa F rdermenge Wasser 7 5 l min F rdermenge maximal 8 3 l min F rdermenge Reinigungsmittel 0 3 l min R cksto kraft der Hoch...

Page 10: ...ump the high pressure jet stops If the lever is pulled the pump is turned on again The motor protection switch switches off the device if the power consumption is high Contents Proper use EN 5 Environ...

Page 11: ...inder For strong contaminations Pressure level HARD 26 Full Control spray lance Vario Power Carrying out the most common cleaning tasks Pressure levels HARD MEDIUM SOFT MIX Optional accessories 27 Plu...

Page 12: ...If the appliance does not build up pressure within 2 minutes switch the appliance off and proceed in accordance with the instructions in Chapter Troubleshooting CAUTION Keep a distance of at least 30...

Page 13: ...ions after opera tion Detach the appliance from the water supply CAUTION Risk of personal injury or damage Mind the weight of the appliance during transport Lift appliance by the carrying handle and c...

Page 14: ...h the lever of the trigger gun first and then switch the power switch to I ON Check setting at the spray lance Check water supply for adequate delivery rate Pull out the sieve in the water connection...

Page 15: ...tion height 0 5 m Performance data Working pressure 12 5 MPa Max permissible pressure 14 5 MPa Water flow rate 7 5 l min Max flow rate 8 3 l min Detergent flow rate 0 3 l min Recoil force of the trigg...