12
English
You can rectify minor faults yourself with the
help of the following overview.
If in doubt, please consult the authorized cus-
tomer service.
Danger
Turn off the appliance and remove the mains
plug prior to any care and maintenance work.
Repair works may only be performed by the
authorized customer service.
Pull on the lever of the trigger gun; the de-
vice will switch on.
Check whether the voltage indicated on
the type plate corresponds to the voltage
of the mains supply.
Check the mains connection cable for
damages.
Check setting at the spray lance.
Remove air from appliance before opera-
tion.
Switch on the appliance without connec-
tion the HP hose (max. 2 minutes) and run
it until the water discharging from the HP
outlet is free of bubbles. Switch off appli-
ance and reconnect HP hose.
Check the water supply.
Pull out the sieve in the water connection
using flat-nose pliers and clean under run-
ning water.
Cause: Voltage reduction due to weak mains
supply or when using an extension cable
.
When switching on, first pull the lever of
the trigger gun and then switch the appli-
ance switch to "I/ON".
Clean high-pressure nozzle: Remove dirt
and debris from the nozzle bore, using a
needle and rinse through with water from
the front.
Check water flow quantity.
Slight leakage from the appliance pump is
normal. If the leakage increases contact
the authorized customer service.
Use spray lance with pressure regulation
(Vario Power).
Turn the spray lance to "Mix" position.
Check the settings at the dosage regula-
tor for detergent.
Check the detergent suction hose for
kinks.
Subject to technical modifications!
Australia
KÄRCHER Pty. Ltd.
40 Koornang Road
Scoresby, Victoria 3179
1800 675 714 (Free Call)
www.karcher.com.au
Troubleshooting
Appliance is not running
Pressure does not build up in the appli-
ance
Appliance does not start, motor hums
Strong pressure fluctuations
Appliance is leaking
No detergent infeed
Technical specifications
Power connection
Voltage
1~50 Hz
240
V
Connected load
2,0
kW
Mains fuse (slow-blow)
10
A
Protective class
I
Protection class
IP X5
Water connection
Max. feed temperature
40
°C
Min. feed volume
10
I/min
Max. feed pressure
0,8
MPa
Max. Suction height
0,5
m
Performance data
Working pressure
12
MPa
Max. permissible pressure
14
MPa
2030
PSI
Water flow rate
7,5
I/min
Detergent flow rate
0 - 0,3 I/min
Customer Service