background image

English

 5

DANGER

Risk of electric shock.

Never touch the mains plug

and the socket with wet

hands.

Check the power cord with

mains plug for damage prior

to every use. Immediately

have damaged power cord

replaced by an authorised

customer service / electrician. 

Do not operate an appliance if

the power cord is damaged.

All current-conducting parts

in the working area must be

protected against jet water.

The mains plug and the cou-

pling of an extension cable

must be watertight and must

never lie in water. Moreover,

the coupling may never lie on

the ground. The use of cable

reels that ensure that the

sockets are at least 60 mm

above the ground is recom-

mended.

Make sure that the power

cord or extension cable is not

damaged by running over,

pinching, dragging or the like.

Protect the power cords from

heat, oil, and sharp edges.

Turn off the appliance and re-

move the mains plug prior to

any care and maintenance

works.

Repair work and work on the

electrical components may

only be performed by an au-

thorised customer service.

WARNING

The appliance may only be

connected to an electric sup-

ply that has been installed by

an electrician in accordance

with IEC 60364.

The appliance may only be

connected to alternating cur-

rent. The voltage must corre-

spond with the type plate of

the appliance.

For safety reasons, we rec-

ommend that you operate the

appliance only via a residual

current device (max. 30 mA).

An unsuitable electrical ex-

tension cable can be hazard-

ous. Only use an electrical

extension cable which has

been approved and labelled

for this purpose and has an

adequate cable cross-section

outdoors: 1 - 10 m: 1.5 mm

2

;

10 - 30 m: 2.5 mm

2

Always fully unreel the exten-

sion cable from the cable

drum.

DANGER

The user must use the appli-

ance as intended. The person

must consider the local condi-

tions and must pay attention

to other persons in the vicinity

when working with the appli-

ance.

Check important compo-

nents, such as high-pressure

hose, hand spray gun and

safety installations, for dam-

age prior to every operation.

Electric components

Safe handling

Summary of Contents for K 2 Compact

Page 1: ...English K 2 Compact Operating Instructions Please read the operating instructions carefully before using the unit 59685910 10 18...

Page 2: ...2 Please refer to packaging to see whether this feature or accessory is included...

Page 3: ...3...

Page 4: ...leads to severe injuries or death WARNING Pointer to a possibly dangerous situation which can lead to se vere injuries or death CAUTION Pointer to a possibly dangerous situation which can lead to mi...

Page 5: ...k and work on the electrical components may only be performed by an au thorised customer service WARNING The appliance may only be connected to an electric sup ply that has been installed by an electr...

Page 6: ...ordingly This appliance is not intended for use by persons with limit ed physical sensory or men tal capacities or lacking expe rience and or skills unless such persons are accompa nied and supervised...

Page 7: ...Type BA Water that has flown through a system separator is no longer classified as drinking water High pressure hoses fixtures and couplings are important for the safety of the appli ance Only use hig...

Page 8: ...t to be cleaned CAUTION Safety installations serve the protection of the user and may not be modified or bypassed The appliance switch prevents unintentional operation of the appliance This lock locks...

Page 9: ...essure hose into the trigger gun Push the clamp in until it locks Check the secure connection by pulling on the high pressure hose Illustration ATTENTION Impurities in the water can damage the high pr...

Page 10: ...the lever of the trigger gun Detach the appliance from the water supply CAUTION Risk of personal injury or damage Mind the weight and storage of the appliance during transport Lift appliance by the c...

Page 11: ...on of the device For information about accessories and spare parts please visit www kaercher com The warranty terms published by the relevant sales company are applicable in each country We will repai...

Page 12: ...feed volume 8 l min Performance data Working pressure 7 4 MPa Max permissible pressure 11 MPa Water flow rate 5 2 l min Max flow rate 6 0 l min Detergent flow rate 0 3 l min Recoil force of trigger gu...

Page 13: ...240 1 50 60 V Hz 6 A IPX5 II 13 A 1 2 MPa 40 C 8 l min 7 4 MPa 11 MPa 5 2 l min 6 0 l min 0 3 l min 10 N 180 mm 219 mm 389 mm 4 5 kg EN 60335 2 79 K 2 5 0 7 m s2 m s2 LpA KpA 78 3 dB A dB A LWA KWA 93...

Page 14: ...7 www kaercher com www kaercher com dealersearch...

Page 15: ...6 5 0 OFF 0 OFF...

Page 16: ...5 KARCHER REACH www kaercher com REACH KARCHER 059 4 730 30...

Page 17: ...4 FFP 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 13 7 5...

Page 18: ...3 30 EN 12729 Typ BA...

Page 19: ...2 60 IEC 60364 30 1 10 m 1 5 mm2 10 30 m 2 5 mm2...

Page 20: ...http www kaercher com service...

Reviews: