background image

14 

English

The scope of delivery of your appliance is il-
lustrated on the packaging. Check the con-
tents of the appliance for completeness 
when unpacking.
In the event of missing accessories or any 
transport damage, please contact your 
dealer.

These operating instructions describe the 
maximum equipment. Depending on the 
model, there are differences in the scopes 
of delivery (see packaging).

Illustrations on Page 2

1 High pressure connection
2 Detergent suction hose (with filter)
3 Appliance switch "0/OFF“/ „I/ON“
4 Storage for high-pressure hose
5 Transport handle, retractable
6 Carrying handle
7 Transport handle lock
8 Storage for spray lance
9 Storage for trigger gun
10 Mains cable with mains plug
11 Connection for water supply with filter 
12 Bearing wheel
13 Coupling element for water connection
14 Trigger gun
15 Lock trigger gun
16 High pressure hose
17 Clamp for high pressure hose
18 Detergent foamer with detergent tank
19 Washing brush
20 Spray lance with Dirtblaster
21 Spray lance with pressure regulation 

(Vario Power)

Special accessories expand the possibili-
ties of using your appliance. Please contact 
your KÄRCHER dealer for further informa-
tion.

Illustrations on Page 2

Mount loose parts delivered with appliance 
prior to start-up.
Illustration 

Î

Insert the transport wheels and lock 
them.

Illustration 

Î

Pull out the clamp for the high-pressure 
hose from the trigger gun (e.g. a small 
screwdriver).

Illustration 

Î

Connect high pressure hose to trigger 
gun.

Î

Push the clamp in until it locks. Check 
the secure connection by pulling on the 
high-pressure hose.

According to the applicable regula-
tions, the appliance must never be 
used on the drinking water supply 
without a system separator. Use a 
suitable system separator manufactured by 
KÄRCHER; or, as an alternative, a system 
separator as per EN 12729 Type BA. Water 
flowing through a system separator is con-
sidered non-drinkable.

Note:

 Impurities in the water can damage 

the high-pressure pump and accessories. 
For protection, the use of the KÄRCHER 
water filter (optional accessory, order no. 
4.730-059) is recommended.

Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.

Î

Use a fibre-reinforced water hose (not 
included) with a standard coupling. 
(Minimum diameter 1/2 inch (13 mm), 
minimum length 7.5 m).

Î

Screw the coupling element (supplied) 
to the water connection on the appli-
ance.

Î

Push the water supply hose onto the 
coupling unit, then connect it to the wa-
ter supply.

Operation

Scope of delivery

Description of the Appliance

Special accessories

Before Startup

Water supply

Water supply from mains

Summary of Contents for K 2-75

Page 1: ...R egister and w in w w w kaercher com Deutsch 3 English 11 Italiano 19 59635990 12 09 K 2 75...

Page 2: ...2...

Page 3: ...de de unternehmen umweltschutz REACH htm In jedem Land gelten die von unserer zu st ndigen Vertriebsgesellschaft herausge gebenen Garantiebedingungen Etwaige St rungen an Ihrem Ger t beseitigen wir in...

Page 4: ...hen Niemals l sungsmittelhaltige Fl ssig keiten oder unverd nnte S uren und L sungsmittel ansaugen Dazu z hlen z B Benzin Farbverd nner oder Heiz l Der Spr hnebel ist hochentz ndlich explosiv und gif...

Page 5: ...r t nur an Wechselstrom an schlie en Die Spannung muss mit dem Typenschild des Ger tes bereinstim men Aus Sicherheitsgr nden empfehlen wir grunds tzlich das Ger t ber einen Fehlerstromschutzschalter m...

Page 6: ...hrem K RCHER H ndler Abbildungen siehe Seite 2 Dem Ger t lose beigelegte Teile vor Inbe triebnahme montieren Abbildung Transportr der einstecken und einras ten Abbildung Klammer f r Hochdruckschlauch...

Page 7: ...eeignet Zum Arbeiten mit Reinigungsmittel geeig net Reinigungsmittel wird aus dem Beh lter angesaugt und es entsteht ein kraftvoller Reinigungsmittelschaum Verwenden Sie zur jeweiligen Reinigungs aufg...

Page 8: ...nsportgriff hochklappen Transportgriffarretierung feststellen Ger t gegen Verrutschen und Kippen sichern Vorsicht Um Unf lle oder Verletzungen zu vermei den bei der Auswahl des Lagerortes das Gewicht...

Page 9: ...ne Spannung auf dem Typenschild mit der Spannung der Stromquelle bereinstimmt Netzanschlussleitung auf Besch di gung pr fen Ger t entl ften Ger t ohne ange schlossenen Hochdruckschlauch ein schalten u...

Page 10: ...ulauftemperatur max 40 C Zulaufmenge min 8 l min Zulaufdruck 0 2 1 2 MPa Leistungsdaten Arbeitsdruck 9 MPa Max zul ssiger Druck 11 MPa F rdermenge Wasser 6 0 l min F rdermenge Reinigungsmittel 0 3 l m...

Page 11: ...tz REACH htm The warranty terms published by the rele vant sales company are applicable in each country We will repair potential failures of your appliance within the warranty period free of charge pr...

Page 12: ...olvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use acetone undiluted ac...

Page 13: ...ype plate on the appliance For safety reasons we recommend that you operate the appliance only via a earth leakage circuit breaker max 30 mA Cleaning operations which produce oily waste water e g engi...

Page 14: ...t loose parts delivered with appliance prior to start up Illustration Insert the transport wheels and lock them Illustration Pull out the clamp for the high pressure hose from the trigger gun e g a sm...

Page 15: ...y K RCHER deter gents and care products to carry out the re spective cleaning task as these were specifically developped for your appliance The use of other detergents and care prod ucts may lead to p...

Page 16: ...ng a storage location for it see Specifications Prior to extended storage periods as dur ing the winter also observe the instructions in the Care section Park the machine on an even surface Insert the...

Page 17: ...late corresponds to the volt age of the mains supply Check the mains connection cable for damages Appliance ventilation Switch the appli ance on with the high pressure hose detached and operate max 2...

Page 18: ...feed temperature 40 C Min feed volume 8 I min Feed pressure 0 2 1 2 MPa Performance data Working pressure 9 MPa Max permissible pressure 11 MPa Water flow rate 6 0 I min Detergent flow rate 0 3 I min...

Page 19: ...tz REACH htm Le condizioni di garanzia valgono nel ri spettivo paese di pubblicazione da parte della nostra societ di vendita competente Entro il termine di garanzia eliminiamo gra tuitamente eventual...

Page 20: ...e pericolosissimi Mantene re una distanza del getto di almeno 30 cm durante la pulizia Rischio di esplosione Non nebulizzare alcun liquido infiam mabile Non aspirare mai liquidi contenenti sol venti o...

Page 21: ...conformit alla norma IEC 60364 Collegare l apparecchio solo a corrente alternata La tensione deve corrispon dere a quella indicata sulla targhetta dell apparecchio Per motivi di sicurezza si consigli...

Page 22: ...pag 2 Prima della messa in funzione montare i componenti singoli dell apparecchio Figura Introdurre ed agganciare le ruote da tra sporto Figura Estrarre il morsetto del tubo flessibile di alta pressio...

Page 23: ...erventi con detergenti Ideal for applications which require a thick foam Simply fill the resevoir cup with liquid pressure washer detergent to generate a foam spray Connects directly to the trigger gu...

Page 24: ...il blocco maniglia per trasporto Bloccare l apparecchio in modo tale che non possa scivolare o ribaltarsi Attenzione Per prevenire incidenti o lesioni nella scelta del luogo di stoccaggio necessario...

Page 25: ...a di eventuali dan ni sul cavo di allacciamento alla rete Eliminare l aria dall apparecchio Ac cendere l apparecchio senza il tubo flessibile di alta pressione collegato ed attendere max 2 minuti finc...

Page 26: ...Temperatura in entrata max 40 C Portata min 8 l min Pressione in entrata 0 2 1 2 MPa Prestazioni Pressione di esercizio 9 MPa Pressione max consentita 11 MPa Portata acqua 6 0 l min Portata detergente...

Page 27: ...27...

Page 28: ...Dublin 12 01 409 77 77 KOR Karcher Co Ltd South Korea Youngjae B D 50 1 51 1 Sansoo dong Mapo ku Seoul 121 060 032 465 8000 MAL Karcher Cleaning Systems Sdn Bhd No 8 Jalan Serindit 2 Bandar Puchong J...

Reviews: