![Kärcher HDS-C 7/11 Manual Download Page 22](http://html.mh-extra.com/html/karcher/hds-c-7-11/hds-c-7-11_manual_655519022.webp)
-
6
Specifications
HDS-C 7/11
SB-HDS 9/15
HDS-C 8/15-E
Electrical connection
Voltage
V/Hz
230/1~/50
400/3~/50
400/3~/50
Connected load
kW (max.)
3,2
6,8
5,6 + 24
Maximum allowed net impedance
Ohm
(0.311+j0.194)
–
Inlet lock
A (slow)
16
16
50
FI safety switch
delta I in A
0,03
0,03
0,03
Water connection
Appliance connection (hose)
Inch
3/4
Max. feed temperature
°C
30
80
Min. feed volume
I/min
16,7
20
16,7
Water pressure
MPa (bar)
0,2...0,6 (2...6)
Performance data
Working pressure with enclosed nozzle
MPa (bar)
11 (110)
15 (150)
15 (150)
Flow rate
l/h (l/min)
660 (11)
900 (15)
740 (12,3)
Nozzle size
052
054
045
Hot water temperature for SB operations limits
°C
70
75
Detergent suction (at 20 °C)
l/h (l/min)
7...9 (0,12...0,15)
Recoil force of the hand-spray gun with enclosed nozzle
N
24
43
29
Burner output, max.
kW
60
86
–
Fuel consumption
kg/h
4,9
6,9
–
Emission temperature
°C
140...160
160...180
–
Dimensions
Width
mm
1040
Depth
mm
727
Height
mm
1360
Weight
kg
245
Miscellaneous
Contents of fuel container
l
25
–
Fuel
Fuel oil EL or Diesel
–
Total contents of the boiler approx.
l
–
55
Boiler capacity of pre-heating chamber approx.
l
–
19
Oil quantity of HP pump
l
0,75
0,75
0,55
Oil grade
15W40
Hypoid SAE 90 Hypoid SAE 90
Values determined as per EN 60355-2-79
Hand-arm vibration value
Hand spraygun
m/s
2
<2,5
Spray lance
m/s
2
<2,5
Uncertainty K
m/s
2
1
Sound pressure level L
pA
dB(A)
54
71
54
Sound power level L
WA
+ Uncertainty K
WA
dB(A)
71
88
71
22
EN