7

OPERATION

*

 Never operate unit with fuel tank

empty! Fuel pump would

otherwise be destroyed!

Switching on unit
Fig. 3

Set selector switch (1) to "I"

Indicator lamp (4) lights

*

 If indicator lamp (2) or (3) comes

on during operation, switch off unit

immediately. Eliminate fault, refer

to Faults.

Unit starts up briefly and is switched

off as soon as operating pressure is

reached.

Illustration 8, Illustration 12

Release handgun

Actuation of handgun switches unit

back on again.
Bleed pump if no water emerges

from high-pressure nozzle. Refer to

Faults "No build-up of pressure by

unit"

Setting cleaning temperature

Set selector switch (1) to desired

temperature
30°C to 90°C

Hot water cleaning
100°C to 150°C

Steam cleaning

(with steam nozzle 4.766-023)

Setting operating pressure and

flow rate

Fig. 9

Turning regulator clockwise:

Increases operating pressure (MAX)

Turning counter-clockwise: Reduces

operating pressure (MIN)

Servopress control

(not HDS 601 C, 1.170-111)

Set selector switch (1) to max. 98°C.

Set regulator to maximum operating

pressure.

Fig. 12

Operating pressure and flow rate

can be set at handgun.

Set pressure on unit if use is to be

made of reduced pressure for a

lengthy period. See Fig. 9

Measuring out the cleaning agent

*

 Use cleaning agents sparingly to

protect the environment

*

 The cleaning agent must be

suitable for the surface to be

cleaned.

Fig. 11

Set cleaning-agent concentration as

specified by manufacturer

0 =Working without cleaning agent
Metering setting

Concentration

1

0,25%

2

1,00%

3

1,25%

4

1,50%

5

1,75%

6

2,00%

Approximate values at maximum

operating pressure

Fig. 16

Take out cleaning-agent inlet

Fig. 17

Turning strainer allows coarse

metering of cleaning agent.

Intended use

Cleaning of: Machines, vehicles,

buildings, tools, facades, terraces,

garden tools, etc..

*

 Heed appropriate safety

regulations for use at petrol

stations or in other hazardous

environments.

Please ensure waste water

containing mineral oil

does not contaminate soil, lakes and

rivers or the sewerage system.

Therefore, please wash engines and

underbodies only in appropriate

washing installations provided with

oil traps.

Summary of Contents for HDS 601 C Eco

Page 1: ...www karcher com 5 959 776 A2005729 04 03 HDS 601 C 1 170...

Page 2: ...HDS 601 C 2 Operating Instructions 5 Spare Parts List 13...

Page 3: ...HDS 601 C 1 3 4 5 6 7 8 9 10 11 12...

Page 4: ...HDS 601 C 13 14 15 16 17 18 19 20 21 22 23...

Page 5: ...pose of packaging environmentally responsibly The packaging materials are recyclable Please do not throw the packaging in with household rubbish but take it to a recycling centre Please dispose of scr...

Page 6: ...n solvent petrol acetone thinner etc Avoid contact with eyes and skin Pay attention to cleaning agent manufacturer s instructions on safety and handling K RCHER can provide an individual range of clea...

Page 7: ...1 170 111 Set selector switch 1 to max 98 C Set regulator to maximum operating pressure Fig 12 Operating pressure and flow rate can be set at handgun Set pressure on unit if use is to be made of reduc...

Page 8: ...ommend the following cleaning temperatures Slight contamination 30 50 C Protein soiling e g in foodstuffs industry max 60 C Motor vehicle cleaning machine cleaning 60 90 C Set selector switch to desir...

Page 9: ...tain degree of corrosion protection is achieved MAINTENANCE Disconnect unit from mains before carrying out any maintenance or repair work Always use genuine spare parts Shut off unit before performing...

Page 10: ...to switch unit on and off several times With handgun open open and close regulator Fig 9 Venting is accelerated by removing the high pressure hose from the high pressure connection Fill up cleaning ag...

Page 11: ...hen reducing water volume at pump head or with the servopress control the overflow valve will open and part of the water will flow back to the pump suction side If the handgun is closed thus causing a...

Page 12: ...550 l h 4 7 9 2 l min Operating pressure cold hot water Mains connection 110 V 3 2 9 MPa 32 90 bar using the supplied standard nozzle Flow rate steam 280 l h 4 7 l min Steam operation mode working pr...

Page 13: ...81 256 0 5 063 858 0 5 363 542 0 4 580 367 0 1 170 104 0 1 170 111 0 OIL MIN 4 067 025 0 6 412 727 0 HDS 601 C 1 170 111 0 GB 4 775 298 0 2 880 296 0 6 362 422 0 6 389 853 0 5 321 493 0 6 303 025 0 6...

Page 14: ...U Harmonised standards applied DINEN60335 1 DINEN60335 2 79 DINEN55014 1 2000 A1 2001 DINEN55014 2 1997 DINEN61000 3 2 2000 DINEN61000 3 3 1995 A1 2001 Relevant EU Directives TRD801 TRD301 DIN2413 Mea...