Changing oil
Fig. 21

 Provide a collecting container for

approx. 1 litres of oil

 Place drainage spout in position

 Loosen starting screw

Fig. 22

KÄRCHER tip

*

 Cut open RM 110 bottle and use

as drainage spout

 Drain off oil via drainage spout into

collector

*

 Dispose of used oil in appropriate

manner or hand in at a collection

point.

 Tighten drain plug again

 Slowly fill with oil as far as MAX

mark

Air bubbles must be able to escape

Refer to technical data for oil grade

and quantity to be used.

FAULTS

FUEL indicator lamp on

Fuel tank empty

 Fill up

READY FOR OPERATION

indicator lamp off

Motor overloaded/overheated

 Set selector switch to "0" and

allow motor to cool down for at

least 5 min.

 Have unit checked by After-Sales

Service if this does not remedy

fault.

SCALE INHIBITOR indicator lamp

on

Scale inhibitor reservoir empty; for

technical reasons there is always a

residual quantity in the reservoir.

 Fill up

Dirt on electrodes in reservoir

 Clean electrodes

Unit does not run

No mains voltage

 Check mains connection/power

cord

Unit does not build up pressure

Air in system

 Bleed pump:

*

 Set cleaning-agent metering to "0"

*

 With handgun open, use selector

switch to switch unit on and off

several times.

*

 With handgun open, open and

close regulator (Fig. 9).

 Venting is accelerated by

removing the high-pressure hose

from the high-pressure

connection.

 Fill up cleaning-agent tank if

empty.

 Check connections and lines

Pressure set to MIN

 Set pressure to MAX

Strainer in water connection dirty

 Clean strainer

Insufficient water supply

 Check water supply volume (refer

to technical data)

Unit leaking, water dripping out at

bottom

Pump leaking

 3 droplets/min are permitted.

 In the event of a major leak, have

unit checked by After-Sales

Service.

Unit constantly switched on and

off with handgun closed

Leak in high-pressure system

 Check high-pressure system and

connections for leaks

Unit does not draw in cleaning

agent

Operate the unit when the cleaning

agent metering valve is open and

the water inlet is shut off until the

float tank has been suctioned empty

and the pressure drops to "0".

 Now reopen the water inlet.

If the pump still does not suction up

cleaning agent the reasons can be

as follows:
Filter in cleaning-agent suction hose

dirty

 Clean filter

Non-return valve gummed up

 Pull the cleaning agent hose off

and detach the non-return valve

with a blunt object, see Figure 23.

Burner not ignited

Fuel tank empty

 Fill up

Lack of water

 Check water connection, check

supply lines, clean low water

protection.

Fuel filter dirty

 Replace fuel filter.

Summary of Contents for HDS 601 C Eco

Page 1: ...www karcher com 5 959 776 A2005729 04 03 HDS 601 C 1 170...

Page 2: ...HDS 601 C 2 Operating Instructions 5 Spare Parts List 13...

Page 3: ...HDS 601 C 1 3 4 5 6 7 8 9 10 11 12...

Page 4: ...HDS 601 C 13 14 15 16 17 18 19 20 21 22 23...

Page 5: ...pose of packaging environmentally responsibly The packaging materials are recyclable Please do not throw the packaging in with household rubbish but take it to a recycling centre Please dispose of scr...

Page 6: ...n solvent petrol acetone thinner etc Avoid contact with eyes and skin Pay attention to cleaning agent manufacturer s instructions on safety and handling K RCHER can provide an individual range of clea...

Page 7: ...1 170 111 Set selector switch 1 to max 98 C Set regulator to maximum operating pressure Fig 12 Operating pressure and flow rate can be set at handgun Set pressure on unit if use is to be made of reduc...

Page 8: ...ommend the following cleaning temperatures Slight contamination 30 50 C Protein soiling e g in foodstuffs industry max 60 C Motor vehicle cleaning machine cleaning 60 90 C Set selector switch to desir...

Page 9: ...tain degree of corrosion protection is achieved MAINTENANCE Disconnect unit from mains before carrying out any maintenance or repair work Always use genuine spare parts Shut off unit before performing...

Page 10: ...to switch unit on and off several times With handgun open open and close regulator Fig 9 Venting is accelerated by removing the high pressure hose from the high pressure connection Fill up cleaning ag...

Page 11: ...hen reducing water volume at pump head or with the servopress control the overflow valve will open and part of the water will flow back to the pump suction side If the handgun is closed thus causing a...

Page 12: ...550 l h 4 7 9 2 l min Operating pressure cold hot water Mains connection 110 V 3 2 9 MPa 32 90 bar using the supplied standard nozzle Flow rate steam 280 l h 4 7 l min Steam operation mode working pr...

Page 13: ...81 256 0 5 063 858 0 5 363 542 0 4 580 367 0 1 170 104 0 1 170 111 0 OIL MIN 4 067 025 0 6 412 727 0 HDS 601 C 1 170 111 0 GB 4 775 298 0 2 880 296 0 6 362 422 0 6 389 853 0 5 321 493 0 6 303 025 0 6...

Page 14: ...U Harmonised standards applied DINEN60335 1 DINEN60335 2 79 DINEN55014 1 2000 A1 2001 DINEN55014 2 1997 DINEN61000 3 2 2000 DINEN61000 3 3 1995 A1 2001 Relevant EU Directives TRD801 TRD301 DIN2413 Mea...

Reviews: