background image

English

HDS 601 C

5

CONTENTS

Environmental protection

 5

Overview

 5

Commissioning

 6

Check the oil level

 6

Filling with scale inhibitor

 6

Filling with fuel

 6

Filling with cleaning agent

 6

Mounting handgun

 6

Water connection

 6

Drawing in water from tank

 6

Mains connection

 6

Operation

 7

Switching on unit

 7

Setting cleaning temperature

 7

Setting operating pressure

and flow rate

 7

Measuring out the cleaning

agent

 7

Intended use

 7

Cleaning

 8

Operation with cold water

 8

Operation with hot water

 8

Operation with steam

 8

Each time after usage

 8

Discontinuation of usage

 9

Maintenance

 9

Maintenance intervals

 9

Maintenance tasks

 9

Cleaning strainer in water

connection

 9

Cleaning strainer in low water

protection

 9

Cleaning filter at

cleaning-agent suction hose

 9

Changing oil

 10

Faults

 10

Warranty

 10

General information

 11

Technical data

 12

Prior to initial startup, operating

manual and safety instructions

no. 5.951-949 must be consulted!

Inform retailer immediately of any

transportation damage.

ENVIRONMENTAL PROTECTION

Please dispose of packaging

environmentally responsibly

The packaging materials are

recyclable. Please do not throw the

packaging in with household rubbish

but take it to a recycling centre.

Please dispose of scrapped units

environmentally-responsibly

Scrapped units consist of valuable

recyclable materials that should be

taken to a recycling centre.

Batteries, oil and similar products

must not be allowed to contaminate

the environment. Therefore, please

dispose of scrapped units via

appropriate disposal systems.

Please ensure engine oil, fuel oil,

diesel and petrol

to contaminate the environment.

Please protect the ground and

dispose of used oil ecologically.

OVERVIEW

Fig. 1

1 Swivel caster with parking brake

2 Connection for high-pressure hose

3 Fuel tank inlet

4 High-pressure hose

5 Cover latch

6 Handgun

7 Pressure gauge

8 Filler opening for cleaning agent

and metering equipment

9 Water connection "1" with strainer

Fig. 3

1 Selector switch ON/OFF and

temperature
Indicator lamps

2 Fuel deficiency

3 Scale inhibitor deficiency

4 Availability

Fig. 4

Press down cover latch with

screwdriver or coin and turn counter-

clockwise to open.

To close, turn clockwise.

Fig. 5

Compartment for accessories

beneath cover

10 Steam nozzle (4.766-023)

optional

Summary of Contents for HDS 601 C Eco

Page 1: ...www karcher com 5 959 776 A2005729 04 03 HDS 601 C 1 170...

Page 2: ...HDS 601 C 2 Operating Instructions 5 Spare Parts List 13...

Page 3: ...HDS 601 C 1 3 4 5 6 7 8 9 10 11 12...

Page 4: ...HDS 601 C 13 14 15 16 17 18 19 20 21 22 23...

Page 5: ...pose of packaging environmentally responsibly The packaging materials are recyclable Please do not throw the packaging in with household rubbish but take it to a recycling centre Please dispose of scr...

Page 6: ...n solvent petrol acetone thinner etc Avoid contact with eyes and skin Pay attention to cleaning agent manufacturer s instructions on safety and handling K RCHER can provide an individual range of clea...

Page 7: ...1 170 111 Set selector switch 1 to max 98 C Set regulator to maximum operating pressure Fig 12 Operating pressure and flow rate can be set at handgun Set pressure on unit if use is to be made of reduc...

Page 8: ...ommend the following cleaning temperatures Slight contamination 30 50 C Protein soiling e g in foodstuffs industry max 60 C Motor vehicle cleaning machine cleaning 60 90 C Set selector switch to desir...

Page 9: ...tain degree of corrosion protection is achieved MAINTENANCE Disconnect unit from mains before carrying out any maintenance or repair work Always use genuine spare parts Shut off unit before performing...

Page 10: ...to switch unit on and off several times With handgun open open and close regulator Fig 9 Venting is accelerated by removing the high pressure hose from the high pressure connection Fill up cleaning ag...

Page 11: ...hen reducing water volume at pump head or with the servopress control the overflow valve will open and part of the water will flow back to the pump suction side If the handgun is closed thus causing a...

Page 12: ...550 l h 4 7 9 2 l min Operating pressure cold hot water Mains connection 110 V 3 2 9 MPa 32 90 bar using the supplied standard nozzle Flow rate steam 280 l h 4 7 l min Steam operation mode working pr...

Page 13: ...81 256 0 5 063 858 0 5 363 542 0 4 580 367 0 1 170 104 0 1 170 111 0 OIL MIN 4 067 025 0 6 412 727 0 HDS 601 C 1 170 111 0 GB 4 775 298 0 2 880 296 0 6 362 422 0 6 389 853 0 5 321 493 0 6 303 025 0 6...

Page 14: ...U Harmonised standards applied DINEN60335 1 DINEN60335 2 79 DINEN55014 1 2000 A1 2001 DINEN55014 2 1997 DINEN61000 3 2 2000 DINEN61000 3 3 1995 A1 2001 Relevant EU Directives TRD801 TRD301 DIN2413 Mea...

Reviews: