– 6
–
Loosen the dirt:
Spray detergent economically and let it
work for 1...5 minutes but do not let it
dry up.
–
Remove the dirt:
Spray off loosened dirt with the high-
pressure jet.
Removal of light contaminations and clear
rinse, i.e.: Gardening tools, terrace, tools, etc.
The appliance works in the most economi-
cal temperature range (max. 60°C).
Danger
Scalding danger!
Set device switch to desired tempera-
ture.
We recommend the following cleaning tem-
peratures:
–
Light contaminations
30-50 °C
–
Contaminations containing protein, i.e.
in the food processing industry
max. 60 °C
–
Vehicle cleaning, machine cleaning
60-90 °C
Set dosing value for detergent to "0".
Set the appliance switch to "1" (opera-
tion with cold water).
Open the hand spray gun and rinse the
appliance for at least 1 minute.
Danger
Danger of scalding by hot water. After oper-
ation with hot water, the device must be op-
erated with open end handgun with cold
water for at least two minutes.
Set the appliance switch to "0/OFF“.
Shut off water supply.
Open the hand spray gun.
Turn on pump shortly (appr. 5 seconds)
with device switch.
Pull main plug out of socket with dry
hands only.
Remove water connection.
Activate hand spray gun until device is
pressure less.
Lock the trigger gun.
Lock in the steel pipe into the holder of
the appliance hood.
Roll up high pressure hose and electri-
cal conduit and hang them into the re-
spective holders.
Note:
Do not twist high pressure hose and
electrical conduit.
Caution
Frost will destroy the not completely water
drained device.
Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
Caution
Threat of damage by penetrating cold air
through the chimney.
Disconnect device from chimney when
outside temperature drops below 0 °C.
If it is not possible to store frost free, shut
down device.
For longer work breaks or if a frost free stor-
age is not possible:
Drain water.
Flush device with anti-freeze agent.
Empty detergent tank.
Screw off water supply hose and high
pressure hose.
Screw off supply hose at boiler bottom
and drain heating spiral empty.
Operate device for max. 1 minute until
the pump and conduits are empty.
Recommended cleaning method
Operating with cold water
Eco level
Operating with hot water
After operation with detergent
Turn off the appliance
Storing the Appliance
Frost protection
Shutdown
Dump water
10