– 4
Your dealer will consult you gladly.
Fill/replace external detergent container.
For connection values refer to technical
specifications
Connect the supply hose(minimu length
24.6 ft/7.5 m, minimum diameter 1/2“)
to the water connection point of the ma-
chine and at the water supply point (for
e.g. a tap).
Note:
The supply hose is not included.
Connect suction hose (minimum diame-
ter 1/2“) with filter (accessory) to the
water connection point.
–
Max. suck height: 1.6 ft (0.5 m)
Danger
Never suck in water from a drinking water
container. Never suck in liquids which con-
tain solvents like lacquer thinner, petrol, oil
or unfiltered water. The sealings within the
device are not solvent resistant. The spray
mist of solvents is highly inflammable, ex-
plosive and poisonous.
–
For connection values, see technical
data and type plate.
–
The electrical connections must be
done by an electrician according to IEC
60364-1.
Set the appliance switch to "0/OFF“.
Plug in the main plug.
STEP 1:
Plug the Ground Fault Circuit
Interrupter (GFCI) into a working outlet.
STEP 2:
Press ’’TEST’’, then press
’’RESET’’ to assure proper connection
to power.
Note: The actual appearance of the
GFCI may be different from this illustra-
tion.
Danger
Risk of explosion!
Do not spray flammable liquids.
Caution
–
Never operate device with empty fuel
tank The fuel pump will otherwise be
destroyed. This also applies to cold wa-
ter operation.
–
Risk of damage! Never operate the ap-
pliance without a filter in the water con-
nection.
–
Risk of damage! Do not place any ob-
jects (hose,etc.) on or over the chim-
ney.
–
Device with hose drum:
Always unwind high pressure hose
completely
몇
Warning
Long hours of using the appliance can
cause circulation problems in the hands on
account of vibrations.
It is not possible to specify a generally valid
operation time, since this depends on sev-
eral factors:
–
Proneness to blood circulation deficien-
cies (cold, numb fingers).
–
Low ambient temperature. Wear warm
gloves to protect hands.
–
A firm grip impedes blood circulation.
–
Continuous operation is worse than an
operation interrupted by pauses.
Water connection
Suck in water from vessel
Power connection
GFCI INSTRUCTIONS
Operation
Safety instructions
9
EN
Summary of Contents for HDS 1.7/12 U Ed
Page 2: ...8 10 4 1 3 21 5 18 31 28 30 29 27 26 15 9 12 11 13 17 16 24 25 20 6 7 2 22 14 13 23 2 1 19 2...
Page 3: ...2 3 1 2 4 5 6 7 8 9 3...
Page 44: ...HDS 1 7 12 U Ed 44...
Page 45: ......
Page 46: ......
Page 47: ......