background image

– 6

ATTENTION

Frost will destroy the not completely water 
drained device.

Store the appliance in a frost free area.

Drain water. 

Pump in conventional frost protection 
agents through the appliance. 

Note:

Use normal glycol-based anti-freezing 
agents for automobiles. 
Observe handling instructions of the anti-
freeze agent manufacturer.

Operate device for max. 1 minute until 
the pump and conduits are empty.

CAUTION

Risk of personal injury or damage! Mind the 
weight of the appliance during transport.

ATTENTION

Protect the trigger from damage during 
transport.

Pull the device behind you at the handle 
for transporting it over longer distances.

Push the handle downward to carry the 
appliance. To carry, hold the appliance 
at the handles and not at the pushing 
handle.

Prior to transporting the appliance in 
horizontal position, remove the deter-
gent bottles from the bottle holder and 
close them.

When transporting in vehicles, secure 
the appliance according to the guide-
lines from slipping and tipping over.

CAUTION

Risk of personal injury or damage! Consider 
the weight of the appliance when storing it.

This appliance must only be stored in inte-
rior rooms.

DANGER

Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
Prior to all work on the appliance, switch off 
the appliance and pull the power plug.

Note:

Used oil must only be disposed of by the 
designated collection points. Please turn in 
used oil there. Polluting the environment 
with used oil is prosecutable.

You can sign with your dealer a contract for 
regular safety inspection or even sign a 
maintenance contract. Please take advice 
on this matter.

Check connection cable for damages 
(risk of electrical shock); get the dam-
aged connection cable replaced imme-
diately by an authorised customer ser-
vice person/ electrician.

Check the high pressure hose for dam-
ages (risk of bursting). 
Please arrange for the immediate ex-
change of a damaged high-pressure 
hose.

Check appliance (pump) for leaks.
3 drops per minute are permitted and 
can come out from the lower side of the 
appliance. Call Customer Service if 
there is heavy leakage. 

Check oil level Please contact Custom-
er Service immediately if the oil is milky 
(water in oil). 

Clean the sieve in the water connection.

Clean filter at the detergent suck hose.

Clean the fine filter. 

Unpressurize the appliance. 

Unscrew the fastening screws of the 
device hood; remove the device hood.

Frost protection

If you cannot store it in a frost-free 
place:

Transport

Storage

Care and maintenance

Safety inspection/ maintenance 

contract

Before each use

Weekly

HD 9/20-4 only:

8

EN

Summary of Contents for HD 7/11-4 M

Page 1: ...HD 7 11 4 M 59669030 11 16 English 3...

Page 2: ...2...

Page 3: ...the operating instruc tions and safety indications Nr 5 951 949 0 Please follow the national rules and regulations for fluid spray jets of the re spective country Please follow the national rules and...

Page 4: ...mation of de posits in the appliance If recycled water is used the following limit values must not be exceeded Safety devices serve for the protection of the user and must not be put out of opera tion...

Page 5: ...gh pressure hose with trigger gun and high pressure connection of the appliance and tighten until hand tight EASY Lock WARNING Risk of injury Appliance accessories sup ply lines and connections must b...

Page 6: ...ance and let it run until the water exiting is bubble free At the end let the appliance run for ap prox 10 seconds then switch off Re peat the procedure for a couple of times Switch off the appliance...

Page 7: ...the detergent sparingly on the dry surface and allow it to react but not to dry Spray off loosened dirt with the high pressure ray After operations dip the filter in clear water Turn the dosing valve...

Page 8: ...startup of ap pliance and electrical shock Prior to all work on the appliance switch off the appliance and pull the power plug Note Used oil must only be disposed of by the designated collection point...

Page 9: ...customer service Call Customer Service in case of elec trical defects Set nozzle to High pressure Clean the nozzle Replace the nozzle Deaerate the appliance see Start up Check water supply level refer...

Page 10: ...declaration shall cease to be valid if the machine is modified without our prior approval The undersigned act on behalf and under the power of attorney of the company man agement Authorised Documenta...

Page 11: ...rating pressure of water using standard nozzle MPa 3 11 Size of standard nozzle 053 Max operating over pressure MPa 20 Flow rate l h l min 300 700 5 11 7 Detergent suck in l h l min 0 40 0 0 7 Max rec...

Page 12: ...http www kaercher com dealersearch...

Reviews: