background image

– 9

Technical specifications

Main Supply

Voltage

V

230...240

Current type

Hz

1~ 50

Motor rpm

1/min

1400

Connected load

kW

3,0

Protection (slow, char. C)

A

13

Type of protection

IPX5

Maximum allowed net impedance

Ohm

0.294+j0.184

Extension cord 30 m

mm

2

2,5

Water connection

Max. feed temperature

°C

60

Min. feed volume

l/h (l/min) 700 (11,7)

Suck height from open container (20 °C)

m

0,5

Max. feed pressure

MPa

1

Performance data

Operating pressure of water (using standard nozzle)

MPa

3...11

Size of standard nozzle

053

Max. operating over-pressure

MPa

20

Flow rate

l/h (l/min) 300...700 (5...11,7)

Detergent suck in

l/h (l/min) 0...40 (0...0,7)

Max. recoil force of trigger gun

N

30

Values determined as per EN 60335-2-79

Hand-arm vibration value
Hand spray gun

m/s

2

1,5

Spray lance

m/s

2

2,6

Uncertainty K

m/s

2

0,3

Sound pressure level L

pA

dB(A)

69

Uncertainty K

pA

dB(A)

3

Sound power level L

WA

 + Uncertainty K

WA

dB(A)

86

Fuel

Amount of oil

l

0,5

Oil grade

SAE 0W40

Dimensions and weights

Length

mm

554

Width

mm

509 

Height

mm

1000

Weight (without accessories)

kg

47,5

11

EN

Summary of Contents for HD 7/11-4 M

Page 1: ...HD 7 11 4 M 59669030 11 16 English 3...

Page 2: ...2...

Page 3: ...the operating instruc tions and safety indications Nr 5 951 949 0 Please follow the national rules and regulations for fluid spray jets of the re spective country Please follow the national rules and...

Page 4: ...mation of de posits in the appliance If recycled water is used the following limit values must not be exceeded Safety devices serve for the protection of the user and must not be put out of opera tion...

Page 5: ...gh pressure hose with trigger gun and high pressure connection of the appliance and tighten until hand tight EASY Lock WARNING Risk of injury Appliance accessories sup ply lines and connections must b...

Page 6: ...ance and let it run until the water exiting is bubble free At the end let the appliance run for ap prox 10 seconds then switch off Re peat the procedure for a couple of times Switch off the appliance...

Page 7: ...the detergent sparingly on the dry surface and allow it to react but not to dry Spray off loosened dirt with the high pressure ray After operations dip the filter in clear water Turn the dosing valve...

Page 8: ...startup of ap pliance and electrical shock Prior to all work on the appliance switch off the appliance and pull the power plug Note Used oil must only be disposed of by the designated collection point...

Page 9: ...customer service Call Customer Service in case of elec trical defects Set nozzle to High pressure Clean the nozzle Replace the nozzle Deaerate the appliance see Start up Check water supply level refer...

Page 10: ...declaration shall cease to be valid if the machine is modified without our prior approval The undersigned act on behalf and under the power of attorney of the company man agement Authorised Documenta...

Page 11: ...rating pressure of water using standard nozzle MPa 3 11 Size of standard nozzle 053 Max operating over pressure MPa 20 Flow rate l h l min 300 700 5 11 7 Detergent suck in l h l min 0 40 0 0 7 Max rec...

Page 12: ...http www kaercher com dealersearch...

Reviews: