English 5.906-565.0 Rev. 00 (12/12)
31
Dismantle the push handle (2 screws) and remove
it.
Remove pressure switch (see "Removing the
pressure switch").
Loosen 4 screws.
Opening the electric casing (see "Opening the
electric casing")
1 Cord grip
2 Screw
Unscrew 2 screws.
Remove the traction relief.
Lift the electric casing and turn it around the right
pipe in an anti-clockwise direction.
Loosen 4 screws.
Remove the lid.
cw: clockwise direction
ccw: anti-clockwise direction
Note:
Only use terminal assignment "cw"!
7.20 Access to the terminal box of the elec-
tric motor