background image

English

7

Storing the cleaner

„

Place the handgun in the support.

„

Reel in the high-pressure hose and hang it 
over the hose rest.

or

„

Wind the high-pressure hose on to the 
hose reel. Push in the crank handle to lock 
the hose drum.

„

Wind the connection cable around the ca-
ble holder.

„

Fix the plug using the installed clip.

Frost protection

Caution!

Frost will destroy a unit that is not com-

pletely empty of water! Store the unit where it 
will be free of frost.

If storage away from frost is not possible:

„

Drain off the water and rinse the unit 
through with anti-freeze.

„

Leave the unit to dry for max. 1 minute.

„

Use the standard glycol-based anti-freezes 
for cars.

„

Follow the handling instructions of the anti-
freeze manufacturer.

Care and maintenance

Danger!

Before any care and maintenance work 

on the unit draw out the mains plug.

Caution!

When changing the oil, dispose of any 

waste oil only at authorised collection points.

Safety inspection/Maintenance 
contract

You can arrange with your dealer to have a reg-
ular safety inspection carried out or to have a 
maintenance contract. Please seek advice.

Before each use

„

Check connecting cable for damage (risk of 
getting an electric shock), have a damaged 
connecting cable replaced without delay by 
authorised Customer Service personnel or 
an electrician.

„

Check high-pressure hose for damage 
(danger of explosion), replace a damaged 
high-pressure hose without delay.

„

Check unit (pump) for any leaks. 
Three drops per minute are allowable and 
can appear on the underside of the unit. 
Seek the help of Customer Service if leaks 
are more serious.

Every week

„

Check oil level in oil reservoir: if the oil is 
milky (water in oil), seek the help of Cus-
tomer Service immediately.

„

Clean the strainer in the water connection.

„

Clean the filter at the suction hose for de-
tergent.

Annually or after 500 operating 
hours

„

Change the oil

– For oil quantity and type see Technical 

Specifications.

– Undo the fastening screw, remove the 

hood, remove the oil tank cover, tilt unit.

– Drain oil into a suitable container.

– Fill slowly with fresh oil; air bubbles have 

to escape.

– Attach the oil tank cover.

Troubleshooting

Danger!

Before any repair work is undertaken, 

switch the unit off and pull out the power plug. 
Have electrical components checked and re-
paired only by authorised Customer Service 
personnel.
For faults which are not identified in this chap-

!

!

Summary of Contents for HD 6/13-4 M

Page 1: ...www kaercher com HD 6 13 4 M HD 7 10 4 M 5 962 555 07 07...

Page 2: ...2...

Page 3: ...for detergent For your safety Before you use the cleaner for the first time read these operating instructions and take special note of the accompanying booklet Safety Instructions for High Pressure Cl...

Page 4: ...while unit is at a standstill The oil level must be above the two indicators Activate the oil reservoir vent Unscrew the fastening screw of the hood and remove the hood Cut off the tip on the cover t...

Page 5: ...is allowed For connected loads see Technical Specifica tions Connect a supply hose not supplied to the water outlet on the unit and to the water in let e g water tap Open water inlet Suctioning water...

Page 6: ...agent suction hose and immerse the filter in the cleaning agent canister Screw on the screw cap on the bottle or can Set nozzle to Set the detergent dosage valve to the desired detergent and the desir...

Page 7: ...se seek advice Before each use Check connecting cable for damage risk of getting an electric shock have a damaged connecting cable replaced without delay by authorised Customer Service personnel or an...

Page 8: ...eaning agent Evacuate air from the cleaner see Switch ing on the unit Seek the help of Customer Service if nec essary Detergent is not being drawn in Set nozzle to Chem Check detergent suction hose wi...

Page 9: ...79 DIN EN 55 014 1 2000 A1 2001 A2 2002 DIN EN 55 014 2 1997 A1 2001 DIN EN 61 000 3 2 2000 DIN EN 61 000 3 3 1995 A1 2001 HD 7 18 4 DIN EN 61 000 3 11 2001 HD 6 16 4 National standards applied Confor...

Page 10: ...on height from an open container 20 C m 0 5 Supply pressure max MPa 1 Performance data Operating pressure MPa 3 13 3 10 Max operating overpressure safety valve MPa 16 13 Flow rate l h l min 250 600 4...

Page 11: ......

Reviews: