background image

English

6

Selecting the type of spray

The handgun must be closed.

„

Rotate the housing of the nozzle until the 
desired symbol corresponds with the 
marking:

High-pressure pencil jet

for particularly stubborn accu-
mulation of grime.

Low-pressure fan jet

for operating with detergent or 
cleaning with negligible pressu-
re.

High-pressure fan jet

for dirt accumulation over a lar-
ge surface.

Operating with detergent

Caution!

Unsuitable detergents can harm the 

cleaner and the object which is to be cleaned. 
Use only detergents which are released by 
Kärcher. Proportions of detergent to be used 
and accompanying instructions should be not-
ed carefully. Use detergents sparingly out of 
consideration for the environment.

Kärcher cleaning agents guarantee trouble-
free operation. Please seek advice or ask for 
our catalogue of information sheets on clean-
ing agents.

„

Put the detergent bottle into the bottle hold-
er at the appliance or place detergent can 
next to the appliance. Two different deter-
gents can be placed in the appliance at the 
same time.

„

Pull out the cleaning agent suction hose 
and immerse the filter in the cleaning agent 
canister.

„

Screw on the screw cap on the bottle or can.

„

Set nozzle to 

.

Set the detergent dosage 
valve to the desired detergent 
and the desired concentration.

Recommended cleaning 

methods

„

Spray detergent with low pressure jet spar-
ingly over the dry surface to be cleaned and 
let it take effect but not dry out.

„

Spray off (rinse off) the loosened dirt using 
the high-pressure spray.

„

After use immerse filter in clean water. 
Turn metering valve to maximum cleaning 
agent concentration setting. Start unit and 
rinse through for one minute.

Interrupting the operation

„

Release lever of the handgun, the unit 
switches off. Retract lever again and the 
unit switches on again.

Switching the unit off

„

Set unit switch to "0" and pull out power plug.

„

Close water inlet.

„

Retract lever until the unit is without pres-
sure.

„

Actuate the handgun's safety catch to se-
cure the handgun lever from accidentally 
being triggered.

Transporting the cleaner

„

To transport the appliance over long dis-
tances use the push handle to pull the ap-
pliance.

„

When carrying the appliance always use 
the handle, not the push handle.

„

Prior to a transport in the horizontal position 
remove the detergent bottles from the bottle 
holder and close them.

Summary of Contents for HD 6/13-4 M

Page 1: ...www kaercher com HD 6 13 4 M HD 7 10 4 M 5 962 555 07 07...

Page 2: ...2...

Page 3: ...for detergent For your safety Before you use the cleaner for the first time read these operating instructions and take special note of the accompanying booklet Safety Instructions for High Pressure Cl...

Page 4: ...while unit is at a standstill The oil level must be above the two indicators Activate the oil reservoir vent Unscrew the fastening screw of the hood and remove the hood Cut off the tip on the cover t...

Page 5: ...is allowed For connected loads see Technical Specifica tions Connect a supply hose not supplied to the water outlet on the unit and to the water in let e g water tap Open water inlet Suctioning water...

Page 6: ...agent suction hose and immerse the filter in the cleaning agent canister Screw on the screw cap on the bottle or can Set nozzle to Set the detergent dosage valve to the desired detergent and the desir...

Page 7: ...se seek advice Before each use Check connecting cable for damage risk of getting an electric shock have a damaged connecting cable replaced without delay by authorised Customer Service personnel or an...

Page 8: ...eaning agent Evacuate air from the cleaner see Switch ing on the unit Seek the help of Customer Service if nec essary Detergent is not being drawn in Set nozzle to Chem Check detergent suction hose wi...

Page 9: ...79 DIN EN 55 014 1 2000 A1 2001 A2 2002 DIN EN 55 014 2 1997 A1 2001 DIN EN 61 000 3 2 2000 DIN EN 61 000 3 3 1995 A1 2001 HD 7 18 4 DIN EN 61 000 3 11 2001 HD 6 16 4 National standards applied Confor...

Page 10: ...on height from an open container 20 C m 0 5 Supply pressure max MPa 1 Performance data Operating pressure MPa 3 13 3 10 Max operating overpressure safety valve MPa 16 13 Flow rate l h l min 250 600 4...

Page 11: ......