background image

English

4

Safety features

Overflow valve with pressure 
switch

On reducing the flow rate with the pressure 
and flow control, the relief valve opens and 
part of the water runs back to the suction side 
of the pump.

If the lever of the hand-held spray gun is re-
leased, the pressure switch switches the 
pump off. If the lever is retracted, the pressure 
switch switches the pump on again.

Safety valve

The safety valve opens when the admissible 
operating excess pressure is exceeded; the 
water flows back to the pump suction side.

Overflow valve, pressure switch and safety 
valve are present in the factory and are 
sealed.

Adjustments are made only by Customer 
Service.

Protection of the 
environment, disposal

Preparing the unit for use

Unpack the unit

– When unpacking the unit, check the con-

tents of the packaging. If there has been 
any damage in transit inform the dealer.

– Do not dispose of the packaging with the 

household rubbish, hand it in at the appro-
priate collection point for recycling.

Check the oil level

„

Read the oil level displayed while unit is at 
a standstill. The oil level must be above the 
two indicators.

Activate the oil reservoir vent

„

Unscrew the fastening screw of the hood 
and remove the hood.

„

Cut off the tip on the cover to the oil reservoir.

„

Fasten the unit cover.

Mount the accessories

„

Mount nozzle on the spray lance (see 
markings on the top of the setting ring).

„

Fit the spray lance to the hand-held spray 
gun with pressure and flow control.

„

Screw on high-pressure hose to the high-
pressure outlet.

Switching on the unit

Electrical connection

Caution!

The appliance may only be connected 

to alternating current. The voltage must corre-
spond with the type plate on the appliance.

Caution!

Use if required an extension cable with 

sufficient cable cross-section (refer technical 
details)and always fully unroll the cable from 
the cable drum. 

The packaging material can be re-
cycled. Please do not place the pak-
kaging into the ordinary refuse for 
disposal, but arrange for the proper 
recycling.

Old appliances contain valuable ma-
terials that can be recycled. Please 
arrange for the proper recycling of 
old appliances. Batteries, oil, and si-
milar substances must not enter the 
environment. Please dispose of your 
old appliances using appropriate col-
lection systems.

Summary of Contents for HD 6/13-4 M

Page 1: ...www kaercher com HD 6 13 4 M HD 7 10 4 M 5 962 555 07 07...

Page 2: ...2...

Page 3: ...for detergent For your safety Before you use the cleaner for the first time read these operating instructions and take special note of the accompanying booklet Safety Instructions for High Pressure Cl...

Page 4: ...while unit is at a standstill The oil level must be above the two indicators Activate the oil reservoir vent Unscrew the fastening screw of the hood and remove the hood Cut off the tip on the cover t...

Page 5: ...is allowed For connected loads see Technical Specifica tions Connect a supply hose not supplied to the water outlet on the unit and to the water in let e g water tap Open water inlet Suctioning water...

Page 6: ...agent suction hose and immerse the filter in the cleaning agent canister Screw on the screw cap on the bottle or can Set nozzle to Set the detergent dosage valve to the desired detergent and the desir...

Page 7: ...se seek advice Before each use Check connecting cable for damage risk of getting an electric shock have a damaged connecting cable replaced without delay by authorised Customer Service personnel or an...

Page 8: ...eaning agent Evacuate air from the cleaner see Switch ing on the unit Seek the help of Customer Service if nec essary Detergent is not being drawn in Set nozzle to Chem Check detergent suction hose wi...

Page 9: ...79 DIN EN 55 014 1 2000 A1 2001 A2 2002 DIN EN 55 014 2 1997 A1 2001 DIN EN 61 000 3 2 2000 DIN EN 61 000 3 3 1995 A1 2001 HD 7 18 4 DIN EN 61 000 3 11 2001 HD 6 16 4 National standards applied Confor...

Page 10: ...on height from an open container 20 C m 0 5 Supply pressure max MPa 1 Performance data Operating pressure MPa 3 13 3 10 Max operating overpressure safety valve MPa 16 13 Flow rate l h l min 250 600 4...

Page 11: ......