background image

– 2

High Pressure. Keep clear of noz-
zle.

If connection is made to a potable 
water system, the system shall be 
protected against backflow.

The owner and/or user must have 
an understanding of the manufac-
turer’s operating instructions and 
warnings before using this pressure 
washer.

Warning information should be em-
phasized and understood.

If the operator is not fluent in Eng-
lish, the manufacturer’s instructions 
and warnings shall be read to and 
discussed with the operator in the 
operator’s native language by the 
purchaser/owner, making sure that 
the operator comprehends its con-
tents.

Owner and/or user must study and 
maintain for future reference the 
manufacturers’ instructions.

This product must be grounded. If it 
should malfunction or breakdown, 
grounding provides a path of least re-
sistance for electric current to reduce 
the risk of electric shock. This product 
is equipped with a cord having an 
equipment-grounding conductor and a 
grounding plug. The plug must be 
plugged into an appropriate outlet that 
is properly installed and grounded in 
accordance with all local codes and or-
dinances.

DANGER

Improper connection of the equipment-
grounding conductor can result in a 
risk of electrocution. Check with a qual-
ified electrician or service personnel if 

you are in doubt as to whether the out-
let is properly grounded. Do not modify 
the plug provided with the product - if it 
will not fit the outlet, have a proper out-
let installed by a qualified electrician. 
Do not use any type of adapter with this 
product.

NOTE - In Canada, the use of a tempo-
rary adaptor is not permitted by the Ca-
nadian Electrical Code.

The HD 1.8/13 is supplied with a 
Ground Fault Circuit Interrupter (GFCI) 
built into the power cord plug. This de-
vice provides additional protection 
from the risk of electric shock. If power 
is interrupted in the line, the GFCI will 
automatically re-close the circuit to the 
load after power is restored. Depend-
ing on the GFCI model, it may be nec-
essary to manually operate the reset 
button to restore power to the GFCI 
load circuit. If replacement of the plug 
or cord is needed use identical re-
placement parts.

CAUTION

When connecting the water inlet to the 
water supply mains, local regulations 
of your water company must be ob-
served. In some areas the unit must 
not be connected directly to the public 
drinking water supply. This is to ensure 
that there is no feedback of chemicals 
into the water supply. Direct connec-
tion via a receiver tank or backflow pre-
venter, for example, is permitted.

Owner/User Responsibility

GROUNDING INSTRUCTIONS

CANADA

HD 1.8/13 only: GROUND 

FAULT CIRCUIT INTERRUPT-

ER PROTECTION 

WATER SUPPLY

5

EN

Summary of Contents for HD 4/9 C

Page 1: ...w w w kaer cher com r egi st er and w i n HD 1 8 13 C Ed HD 4 9 C 59663590 03 15 English 4 Fran ais 16 Espa ol 29...

Page 2: ...3...

Page 3: ...safety feature DOES NOT lock trigger in the ON position 12 Keep operating area clear of all per sons 13 Close cover before operating the machine 14 This appliance is intended for com mercial use 15 Fo...

Page 4: ...ified electrician or service personnel if you are in doubt as to whether the out let is properly grounded Do not modify the plug provided with the product if it will not fit the outlet have a proper o...

Page 5: ...xtension cords that have 3 prong grounding type plugs and 3 pole cord connectors that accept the plug from the product Use only ex tension cords that are intended for out door use These extension cord...

Page 6: ...dle bottom slid in 27 Push handle top extended 28 Storage compartment for hoses 29 Cable clamp 30 Spray lance holder without clamp ing The operating elements for the cleaning process are yellow The co...

Page 7: ...t of operation or bypassed with respect to their function If the lever on the trigger gun is re leased the pressure switch turns off the pump the high pressure jet is stopped If the lever is pulled th...

Page 8: ...not included Open the water supply Screw the suction hose with filter optional accessory to the water connection Appliance ventilation Unscrew the nozzle from the spray lance Switch on the appliance a...

Page 9: ...e lever of the gun Close the hand spray gun Turn the casing of the nozzle till the desired symbol matches the mark ing WARNING Unsuitable detergents can cause dam age to the appliance and to the objec...

Page 10: ...se cure it by means of the rubber band Fasten the plug with the mounted clip Press the unlocking device of the push handle and slide the push handle in Warning Frost will destroy the not completely wa...

Page 11: ...operly trained crane personnel Do not stand below the load Ensure that no persons are present in the immediate vicinity of the crane Do not leave the appliance on the crane unattended CAUTION Risk of...

Page 12: ...oned in this chapter or if you are in doubt or when you have been explicitly asked to do so Check connection cable for damag es Check the supply voltage If the appliance is overheated Set the applianc...

Page 13: ...d list of spare parts that are often required For additional information about spare parts please go to the Ser vice section at www kaercher com The warranty terms published by the relevant sales comp...

Page 14: ...erformance data Working pressure PSI kPa 1300 9000 Nozzle size 032 Max operating over pressure PSI MPa 1800 12 5 Water flow rate GPM l min 1 8 6 8 Detergent suck in GPH l h 0 6 6 0 25 Max recoil force...