English
7
ing on the GFCI model, it may be nec-
essary to operate the reset button to
restore power to the GFCI load circuit.
If replacement of the plug or cord is
needed use identical replacement
parts.
WATER SUPPLY
몇
CAUTION
When connecting the water inlet with
the water supply mains, local regula-
tions of your water company must be
observed. In some areas the unit must
not be connected directly to the public
drinking water supply. This is to ensure
that there is no feedback of chemicals
into the water supply. Direct connec-
tion via a receiver tank or backflow pre-
venter, for example, is permitted.
Dirt in the feed water will damage the
unit. To avoid this risk, we recommend
fitting a water filter.
Garden hose must be at least 1 inch
in diameter.
Flow rate of water supply must not
fall below 4 GPM (gallons per min-
ute).
Flow rate can be determined by run-
ning the water for one minute into an
empty 4-gallon container.
The water temperature must not ex-
ceed 140° F/60° C.
Never use the pressure washer to
draw in water contaminated with sol-
vents, e.g. paint thinners, gasoline,
oil, etc.
Always prevent debris from being
drawn into the unit by using a clean
water source. Use additional water
filter.
General notes
Read these original operat-
ing instructions and the en-
closed safety instructions before using
the device for the first time. Proceed
accordingly.
Keep both books for future reference
or for future owners.
Intended use
Use this high-pressure cleaner only for
the following types of work:
Clean machines, vehicles, structures,
tools and similar objects with the high-
pressure jet.
We recommend using a rotary nozzle
as a special accessory for stubborn
soiling.
A rotary nozzle is supplied in the scope
of delivery for the HD...Plus.
ATTENTION
Contaminated water leads to prema-
ture wear and tear or deposits in the
device.
Supply the device using only clean wa-
ter, or recycled water that does not ex-
ceed the following specified limit
values:
pH value: 6.5...9.5
Electrical conductivity: Conductivity
of fresh water + 1200 µS/cm, maxi-
mum conductivity 2000 µS/cm
Settleable particles (sample volume
1 l, settling time 30 minutes):
< 0.5 mg/l
Filterable particles: < 50 mg/l, no
abrasive substances
Hydrocarbons: < 20 mg/l
Chloride: < 300 mg/l
Sulfate: < 240 mg/l
Calcium: < 200 mg/l
Total hardness: < 28 °dH, < 50° TH,
< 500 ppm (mg CaCO
3
/l)
Iron: < 0.5 mg/l
Manganese: < 0.05 mg/l
Copper: < 2 mg/l
Active chloride: < 0.3 mg/l
Free of unpleasant odors