29
Maintenance
Thermostat
This machine uses a three-phase thermostat. A three-
phase thermostat is a complex component; it is difficult
to test in the field. Please contact your customer
service representative for testing instructions.
Start Capacitor
1.
Disconnect power to the machine.
2.
Remove the turntable motor cover
(two 5/16" screws).
3.
Inspect the start capacitor. If it appears swollen or
deformed, it is no longer functional; replace the
start capacitor.
4.
If the start capacitor has not visibly failed, remove it
from the motor bracket, disconnect the wires, and
test it for shorts using an ohm meter.
If the ohm meter reads approximately 1 ohm, the
start capacitor is no longer functional; replace it.
CUDA 7248 Operator’s Manual 9.801-712.0 - AA
Start
Capacitor
Motor
Cover
Screws