10
Operations
Installation
Before You Begin
To prepare to install the machine, choose an unob-
structed, level site that allows convenient access for
operators and maintenance personnel. Sources for
water and electrical power should be located near the
installation site.
If you have any questions regarding the installation,
please contact your distributor or call a customer
service representative. When contacting customer
service please refer to the machine identification tag
inside the front cover of this manual for detailed
machine specifications.
Step 1: Make Electrical Connections
NOTE:
All electrical installation tasks must be
performed by a licensed, professional electrician
to ensure safe and proper operation.
The
installation must comply with the National Electric
Code and all applicable state and local codes.
The machine can only operate on the type of elec-
trical power indicated on the electrical specifica-
tions tag.
Read and understand the electrical
specifications tag to determine the electrical power
requirements before installing the machine.
Step 2: Connect A Compressed-Air Line
And Accessories
This step is required for machines equipped with the
optional power brush and hand detail brush. If your
machine does not have these options, skip the
following procedure.
NOTE:
To ensure proper operation and to minimize
the possibility of premature component failure, make
sure the compressed air is supplied at 75 to 90 psi.
Manufacturer also recommends an in-line moisture
trap and an in-line lubricator on the main air supply
line. Refer to the documentation provided with the
power brush for more information.
1.
Remove the power brush from the box, install the
wire brush in the chuck, and connect the air hose.
2.
Familiarize yourself with the three-way air flow
valve, then install a fitting to accommodate a
connection to your compressed-air supply.
3.
Connect the shop compressed-air line to the
machine.
4.
Connect the hose from the power brush to the air
flow valve.
5.
Hang the power brush on the bracket mounted on
the right side of the machine.
Step 3: Connect A Water Line
This step is required for machines equipped with the
optional automatic water fill system. If your machine
does not have this option, skip this step.
CUDA 7248 Operator’s Manual 9.801-712.0 - AA
Terminal Block
Grounding
Lug
GR
OUND
Outlet to
Power Brush
3 Way Air
Valve
Outlet to
Compressed Air
Outlet to