– 8
Pump stops, two pairs
of lights blink, alter-
nating sides.
Failure in the pressure
line, flow too small, the
pump frequently
switches on and off as
a result of reduced wa-
ter extraction.
If reduced water extraction is required, the
switching frequency can be reduced by in-
creasing the overpump time, and thus the
occurrence of this failure can be avoided.
Restart the pump by continuously press-
ing the - button.
Failure in the pressure
line, the pump fre-
quently switches on
and off as a result of
leakage.
Check and correct the pressure line for
leakages (dripping water tap).
Restart the pump by continuously press-
ing the - button.
Pump stops intermit-
tently and turns back
on. After several cy-
cles, two pairs of lights
blink, alternating sides
Pressure loss due to
missing or defective
backflow valve
Ensure that the backflow valve is correctly
inserted into the fill neck.
Observe the care instructions.
Pressure reduction by
leakages in the system
Check all connection locations on the suc-
tion and pressure sides as well as all the
lids for tightness.
Install a pressure compensating hose on
the pressure side (see special accesso-
ries). As an alternative, a pressure com-
pensating container can be installed as a
pressure tank.
Pump transports is re-
ducing or transported
quantity is too low
Suction pipe blocked
Pull out the mains plug and clean the suc-
tion pipe
Pre-filter is dirty
Remove the prefilter and the backflow
valve and clean them under flowing water,
rinse any dirt residues from the fill neck by
opening the discharge opening.
Suction side is leaky
Check the entire suction side for leaks
The quantity transport-
ed by the pump de-
pends on the transport
height and the connect-
ed periphery
Keep max. flow height, see technical data.
If necessary, select a different hose diam-
eter or hose length.
Fault
Cause
Remedy
Our Kärcher branch will be pleased to help you further in the case of questions or faults.
See address on the reverse.
22
EN
Summary of Contents for BPE 4000/45
Page 2: ...2...
Page 3: ...3...
Page 74: ...1 35 C REACH www kaercher com REACH EL 1 EL 2 EL 3 EL 5 EL 5 EL 5 EL 6 EL 7 EL 9 EL 11 74 EL...
Page 75: ...2 3 2m 30mA 30mA 75 EL...
Page 77: ...4 10 K rcher 1 4 min 77 EL...
Page 78: ...5 Til overvintring og l ngere opbevaring 5 78 EL...
Page 82: ...9 82 EL...
Page 83: ...10 2 2 K rcher 83 EL...
Page 85: ......