– 3
Please follow the safety instructions before
start-up!
The automatic house water system main-
tains the pressure in the mains automatical-
ly. The pump is turned on if the pressure
falls below 0.16MPa (1.6 bar). The pump
runs as long as the flow meter detects a
water extraction (flow > 200 l/h). If the water
extraction is finished, the pump is turned off
after a short trailing period. The system is
now under pressure. In the case of re-
newed water extraction and the resulting
pressure drop, the pump starts again.
The pump remains turned on for a 3 second
period (“overpump time”) after the extrac-
tion is finished to build up the required pres-
sure again. This period can be adjusted if
needed.
It should be increased if the pump is fre-
quently switched on and off (in the case of
reduced water extraction or system leak-
age).
Under ideal conditions, it can be reduced to
save energy.
Use the + / - buttons to adjust the overpump
time. The active light shows the current set-
ting (20s/10s/5s/3s).
If the pump is inactive for an extended peri-
od of time, the LEDs will switch from a con-
tinuous light to the energy conservation
mode and will then blink approx. 1 time per
minute.
A blinking LED during pump operation sig-
nals an active water flow.
1 Power cord with plug
2 Connection G1(33.3mm) Pressure pipe
3 Filling nozzle
4 Cover with prefilter and built in backflow
valve
5 Drain opening
6 Connection G1(33.3mm) Suction pipe
7 Drain cover with flow meter and safety
device
8 ON/OFF switch
9 Operation buttons
10 Overpump time indication.
Please follow the safety instructions before
start-up!
Illustration
Connect anti-vacuum suction hose with
backflow stop valve on the suction side.
(see special accessories)
Note:
Please use original Kärcher suction
lines, filter components and hose connec-
tions. If components made by other manu-
facturers are used, there can be
malfunctions when suctioning the liquid,
especially if you are using bayonet connec-
tion systems.
With fixed installations:
Connect the
pressure side to the pressure line using
a flexible pressure compensating hose
to reduce noise (see special accesso-
ries).
Tip:
To make subsequent empting of the
system and pressure release easier, we
recommend you install a shut-off valve be-
tween pump and pressure line.
(not included in delivery)
By closing the shut-off valve when empty-
ing the pump you can prevent water from
escaping from the pressure line.
Operations
System operation
Settings
Description of the Appliance
Preparing the Appliance
17
EN
Summary of Contents for BPE 4000/45
Page 2: ...2...
Page 3: ...3...
Page 74: ...1 35 C REACH www kaercher com REACH EL 1 EL 2 EL 3 EL 5 EL 5 EL 5 EL 6 EL 7 EL 9 EL 11 74 EL...
Page 75: ...2 3 2m 30mA 30mA 75 EL...
Page 77: ...4 10 K rcher 1 4 min 77 EL...
Page 78: ...5 Til overvintring og l ngere opbevaring 5 78 EL...
Page 82: ...9 82 EL...
Page 83: ...10 2 2 K rcher 83 EL...
Page 85: ......