– 12
Faults without display
Fault
Remedy
Appliance cannot be
started
Check battery; charge it, if needed
Check battery pole fuse at the positive pole of the battery (75 A);
inform customer service if the fuse is defective.
Insufficient water quan-
tity
Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.
Insufficient vacuum per-
formance
Check the condition of the seals between waste water tank and
cover, replace if required.
Clean the fluff filter
Clean the vacuum lips on the vacuum bar, turn or replace if re-
quired
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Insufficient cleaning re-
sult
Check the brushes for wear, replace if required.
Brushes do not turn
Check if foreign matters block the brushes; remove foreign matter
if required.