User’s Manual
8-zone Telephone Alarm System
Page 1: ...User s Manual 8 zone Telephone Alarm System...
Page 2: ...8 3 How To Set Telephone Attribute 9 4 How To Set Cycle Times Of Dialing 9 5 How To Open Close Telephone Line Cut Detect Function 9 6 How To Set Ringing Times Of Operation Remotely 9 5 5 Alarm Monitor...
Page 3: ...When Power On Main Unit 15 8 3How To Alarm 15 8 4How To Operate When Receipt Of Alarm Telephone 15 8 5How To Control Remotely 16 9 Technical Parameter 17 10 Standard Packing List 18 11 Optional Packi...
Page 4: ...motely Operation It can be armed disarmed remotely by entering code through fix telephone or mobile phone Only B model have this function It indicates by sound and light when power lower of main unit...
Page 5: ...lower SET Indicator Orange This light will be on when main unit enter setting state and it will be off when main unit exit from setting state ALARM Indicator Red This light will be on when main unit o...
Page 6: ...ed to send receive wireless signals pulling it out is recommended to assure to get the best effect 3 3 Bottom Components Of Main Unit Picture 3 Microphone It is used to monitor Anti slip footpad It pr...
Page 7: ...correctly connected if the connection is correct please try another telephone set Main unit will make a short Du sound every time pressing keyboard on telephone therefore during setting you can adjust...
Page 8: ...that of at home mode After that press to confirm and it will make four short Di sound which means the setting is successful 2 How To Set Zone List Of Away Home Mode 12345678 by default 02 XXXXX X is a...
Page 9: ...ew code and it should be any number ranges from 0 to 9 Instruction After entering 09 you will hear a short Di sound then you can enter 6 bits new code and press a to confirm after hearing a short Di s...
Page 10: ...utomatically 8 How To Set Delay Alarm Time Entering Time 00 second by default 27 DD Instruction DD is delay alarm time which ranges from 00 to 99 and it should be 2 bits Delay alarm time is only valid...
Page 11: ...er like this 12 1234567 801 and the number of is subject to the needs 2 How To Delete Telephone Numbers Example 1 Delete the second group of telephone number Directives Instruction 11 Telephone Number...
Page 12: ...curs alarm it will dial the alarm telephone number from the first group to the last group and it means one cycle When the cycle dialing times you set arrives main unit will hang telephone up and stop...
Page 13: ...nds SET indicator will be on and it needs to wait For 2 seconds after picking up receiver Enter 12 48 12 48 is the code of manager and can not be modified If the code is incorrect then SET indicator w...
Page 14: ...rong signals please delete it according to the 6 3 chapters and then learn code again 3 How To Delete Detector 11 to delete the first detector in the first zone 12 to delete the second detector in the...
Page 15: ...lashing then press Disarm key on remote controller it will make four short Di sound which means the setting is successful then the indicator light of the first zone will be off Then enter 93 and the i...
Page 16: ...or not after checking power main unit and all accessories down then begin to install 7 2 Install Requirements Firstly make a scheme of all defense zones according to user s needs and the surroundings...
Page 17: ...sensor part should not beyond 10mm The magnetic part should be installed in moveable place such as door or window and the sensor part should be installed in the fix place Pull the antenna out to get t...
Page 18: ...re are power lower occurs in main unit then the power indicator light of it will be flashing then please charge in time If there are power lower occurs in detector then the indicator light of this det...
Page 19: ...ot with the loudest volume and if you enter 2 main unit will disarm and stop alarming on the spot If you don t want it to dial other telephone numbers you can press 1 main unit will enter arm state im...
Page 20: ...ations for 20 seconds main unit will hang up automatically 9 Technical Parameter 9 1Main Unit A B model Working Voltage AC220V 15 50Hz Working Current Standby Current 26mA Alarm Current 350mA Battery...
Page 21: ...reless Remote Controller Wireless Door Sensor Wireless PIR Detector Wireless Emergency Button Wireless Smoke Detector Wireless Gas Detector Wireless Siren AA Ni MH Rechargeable Battery Question Reason...
Page 22: ...tly incorrect place Place according to requirements The telephone can not dial 1 The outside line is parallel 1 Extension should be connected out while alarming connecting with extension with the tele...
Page 23: ...m sound is in the middle 23 Alarm sound is louder 24 Alarm sound is the loudest 25 DD Alarm duration DD 00 99 Minutes 30 minutes by default 26 DD Leaving time DD 00 99 Seconds 00 second by default 27...
Page 24: ...zone 12 Learn the second detector in the first zone 13 Learn the third detector in the first zone Deduce by analogy 81 Learn the first detector in the eighth zone 82 Learn the second detector in the e...
Page 25: ...spot Directives Of Operation Remotely User s Code 000 000 At Home Zone List All zones Away Home Zone List All zones Zone Attribute 111 111 Telephone Type 111 111 Monitor Accounts 00 00 Alarm Telephon...
Page 26: ...nment temperature when the temperature of protected area reach to 32 40 the performance of infrared detector detect distance will reduce So we suggest you to check its working performance carefully wh...