![Kapat KARAT-520 Operation Manual Download Page 6](http://html.mh-extra.com/html/kapat/karat-520/karat-520_operation-manual_653101006.webp)
1. DESCRIPTION AND OPERATION
1.1. Purpose and application
KARAT-520 ultrasonic flowmeters are designed for industrial and
commercial metering of volume flow and liquid volume in filled pipe-
lines of heating systems, cold and hot water supply under conditions
of round-the-clock service. The flowmeters can be used as a part of
heat meters or measuring systems.
1.2. Design version
Flowmeters are
devices
which measure flow rate and volume.
The present devices are produced in accordance with technical re-
quirements TR 4213-009-32277111-2012.
As for design the flowmeters differ in nominal diameter, power supply
type, output signals type (or types combination), construction of mo-
unting elements.
microprocessor measuring and calculating
КАRАТ-520 - ХХ - Х - АR
Flowmeter
description
Dimension type
of the flowmeter (ND):
,
,
,
,
,
,
20 25 32 40 50 65 80
Design variant of the flowmeter:
, , , ,
0 1 2 3 4
Additional functions:
— the flowmeter has flow archives ( in the absence of
symbol, there are no archives in the flowmeter)
— the flowmeter has normalized characteristics
of reverse flow measurement (in the absence of symbol
characteristics of reverse flow measurement are not
normalized)
A
A
R
R
Flowmeters designation in technical and maintenance documenta-
tion of “Uraltechnology” RPE is the following:
СМАФ.407251.002 РЭ – Operations manual
Edition 3.0. August 2012
6
КАRАТ-520
Ultrasonic flowmeters
КАRАТ RPA
www.karat-npo.ru