DN1726-0811
3
KT-400 Ethernet Four-Door Controller Installation Manual
Compliance Specifications
FCC & IC Compliance
This device complies with Part 15 of the FCC rules Class A. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received including
interference that may cause undesired operation. This class A digital apparatus meets all requirements of the Canadian
Interference Causing Equipment Regulations. The KT-400 Ethernet Four-Door Controller is also compliant with
EN55022:1998, amendment 1:1995, Class A.
UL Compliance
To comply with UL listings, the following requirements must be met:
•
Use of a UL listed computer
•
Use of UL listed readers (Wiegand 26 and 34 bits, mag stripe 26 and 34 bits, XSF 39 bits have been tested and found to
comply)
•
Use of a UL recognized tamper switch on every housing cabinet for the KT-400 Ethernet Four-Door Controller
•
Do not use the SmartLink option
•
Do not use a 240 VAC transformer (not UL listed)
•
Use only UL listed cables
•
Use only UL listed adaptors
•
Use only a UL listed transformer
Hammond BF2F
such as Kantech part number
TR1675
(Available through Kantech
distributors or dealers, please refer to the Technical Support contact information
on page 2
to obtain the specific
transformer)
Note:
All circuits are power limited.
UL 294 Compliance Notice
•
IP Connectivity:
Only for supplementary use when planning to install the KT-400 Ethernet Four-Door Controller with a
UL 294 access control system.
•
Use only UL 294 or UL 1076 listed power supply
•
Connect Kantech part number
KT-ACPW-LED
status indicator to the
16 VAC
black terminals of the KT-400
•
Use Kantech part number
KT-BATT-12
battery, see
Note
.
Note:
Backup battery provides operation of up to 12 hours but has been tested for 4 hours per Section 33 of UL 294,
fifth edition.
UL 1076 Compliance Notice
•
The KT-400 is UL 1076 Listed as a Commercial Proprietary Control Unit Accessory and Proprietary Burglar Alarm
Unit (Section 83.2), with EntraPass and Redundant Server, alarm system features, KT-300 Controllers, ioProx
Proximity readers, and TRex request to exit devices – other sensor devices (temperature, water level, etc.) may
be used as long as they are also UL 1076 Listed.
•
The EntraPass and Redundant Server shall be running at all time, and manned 24 hours a day, 365 days a year
– The EntraPass and Redundant Server will each have their own operator workstation.
•
Data processing equipment and office appliance and business equipment used as central supervisory equipment
station shall be listed to Information Technology Equipment - UL 60950.
•
Should the EntraPass and/or Redundant Server be replaced, a UL 60950 listed computer must be used.
•
The following recommended system requirements apply to the EntraPass Server, Redundant Server, Video Vault,
Card Gateway, SmartLink, and Workstation:
•
Operating Systems: Windows® 2000/XP/2003 Standard and Enterprise Server Editions/Vista
•
Processor: Pentium IV at 1.8 GHz
Summary of Contents for Ethernet Four-Door Controller KT-400
Page 1: ...DN1726 0811 KT 400 Ethernet Four Door Controller Installation Manual ...
Page 2: ......
Page 12: ...DN1726 0811 8 Figure 1 KT 400 Ethernet Four Door Controller PCB View ...
Page 14: ...DN1726 0811 10 Figure 3 KT 400 Cabinet Model for North America ...
Page 30: ...DN1726 0811 26 Figure 10 PCB View of Expansion Modules ...
Page 32: ...DN1726 0811 28 Figure 12 Expansion Modules Cabinet for North America ...
Page 44: ...DN1726 0811 40 ...