DN1726-0811
32
Configuring the KT-400 Ethernet Four-Door Controller with the Web
Configuration Page
This procedure is practical if you want to configure the KT-400 in advance before going on site.
Optional Documentation
Application Note,
Networking Basics
, DN1796.
Before you start
•
The detachable
Network Configuration Information Sheet
is fully completed.
•
Determine your connection to the KT-400 and choose the appropriate network cable that you need.
1. Make sure the KT-400 is in
Forced Default Static
mode before starting the configuration. Verify the heartbeat patterns to
determine the status. See
Table 3 on page 29
for details.
2. Start your web browser and enter the following IP: 192.168.1.2 and press
Enter
.
3. Put a jumper on
JP3
. Both jumpers should now be on
JP2
and
JP3
.
4. Enter the IP addresses as per the
Network Configuration Information Sheet
and click on
Save configuration to KT-400
.
5. When you will go to the site with the configured KT-400, you will have to enter the same details into the EntraPass
workstation.