DN1726-0811
14
VITAL LED Heartbeat Patterns
Communication status and other vital controller parameters can be obtained from VITAL LED heartbeat patterns. It is
located near the RS-232 port (COM3), see
Figure 1
. This information is particularly useful when connecting the
controller to the rest of the EntraPass system. The following table lists all conditions along with a brief description. Refer
to
Table 3
, if you must reset or change the communication mode of the KT-400 Ethernet Four-Door Controller.
Table 1: VITAL LED Heartbeat Patterns
Booting Up
Steady
Factory Default DHCP
Continuous LONG Pulses
Unable to Resolve DNS
2 LONG Pulses
Forced Default Static
3 LONG Pulses
DHCP Server Failed
4 LONG Pulses
Receive Broadcast
Single 2.5 Sec. Burst
Card Read or Swipe
Single 0.5 sec burst, resume
previous flash
Hard Reset
4 SHORT Pulses
Corporate Gateway
3 SHORT Pulses
Global Gateway
1 SHORT Pulse
Fail Soft
Continuous SHORT Pulses
Firmware Update
5 pulses / sec @ 50% duty cycle
Rebooting
10 pulses / sec @ 50% duty cycle