Once wiring is completed, the module must be assigned to the system. To assign the module, perform the following:
1. Establish communication between the PC and the controller.
2. Remove the tamper switch wire (or only the wire if tamper switch is not used).
3. A serial number should be displayed in the EntraPass message desktop. Look for the type of module and the
controller to which it is connected.
4. From the EntraPass controller definition window, select the functionality of the module and enter the serial
number in the appropriate field (refer to Chapter 4, Defining Devices or your EntraPass Reference Manual for
more details).
5. If the module is used in “repower” mode, assign an “Always valid” schedule to relay 1 and assign the module’s
functionality to “relay 1 to 4” in the EntraPass software.
NOTE:
Do not forget to reconnect the tamper switch (or the wire, if there is no tamper switch).
NOTE:
Ensure that Jumper J1 is set to “Combus Relay” position if used as “repower”.
KT-PC4216 - 16-Zone Output Expansion Module
KT-PC4216 Introduction
The KT-PC4216 module is an open-collector to 12 VDC 16-zone output module. Can be used for elevator access control (may
require additional hardware).
KT-PC4216 Specifications
•
16-output low current module, 12 VDC, 50 mA max. each, power drawn from
Combus (since Combus can handle a maximum of 500 mA, a KT-PC4204 module
in “repower” mode can be used to increase the current of the Combus of 1A).
•
Connects to KT-300 via 4-wire Combus
•
Nominal current draw of 15 mA
•
Tamper contact input
•
Can be used for elevator control
Unpacking the KT-PC4216
The KT-PC4216 package should include the following parts:
•
One KT-PC4216 circuit board
•
4 plastic standoffs
Mounting the KT-PC4216
The KT-PC4216 should be located inside a compatible cabinet (part no. KT-4501CAB),
mounted in a dry, secure location. It should be placed at a convenient distance from the
connected devices. Perform the following steps to mount the units:
1. Press the four plastic standoffs through the mounting holes at the back of the
cabinet.
2. Secure the cabinet to the wall in the desired location. Use appropriate wall
anchors when securing the cabinet to drywall, plaster, concrete, brick or other
surfaces.
3. Press the circuit board into the plastic standoffs to secure the module to the
cabinet.
Wiring bay be started once the unit is mounted.
Installation and Wiring
Before beginning to wire the unit, ensure that all power (AC transformer and battery) is
disconnected from the controller. Perform the following steps to complete wiring:
1. Connect the four Combus wires to the KT-PC4216. Connect the Red, Black,
Yellow and Green Combus wires to the RED, BLK, YEL and GRN terminals,
respectively.
2. Complete all output wiring as illustrated on the next page.
3. Connect the external tamper switch, if used.