19
6666----4 Needle height
4 Needle height
4 Needle height
4 Needle height
When the needle bar is at the top of its stroke, remove plug A on the side cover plate,
loosen screw C on needle bar clamp B with a hexagonal wrench and then move the
needle bar up or down as required.
< Standard needle bar height D >
Stroke Standard
model
34mm 13.5mm
【
7
】
ADJUSTING THE TIMING OF THE RETAINER LOOPER
7777----1 Position of the retainer looper
1 Position of the retainer looper
1 Position of the retainer looper
1 Position of the retainer looper
Install retainer looper A so that its flat surface is
turned upward. At this time, there should be a
clearance of 0.5mm between the needle and the point
of the retainer looper. Adjustment is made by
loosening
B.
< Note >
After the above adjustment is made, check to make sure each needle drops correctly into the
center of each needle drop hole.
Summary of Contents for DFB1012P
Page 6: ...3 Threading diagram for DFB1404 ...
Page 7: ...4 Threading diagram for DFB1406 ...
Page 8: ...5 Threading diagram for DFB1412 ...
Page 9: ...6 Threading diagram for DFB1412PSM ...
Page 10: ...7 Threading diagram for DFB1412PQ ...
Page 11: ...8 Threading diagram for DFB1012 ...
Page 12: ...9 Threading diagram for DFB1012PSM ...
Page 16: ...13 1406 1412 1012 ...
Page 17: ...14 1412 1012PSM ...
Page 18: ...15 1412PQ ...
Page 19: ...16 1412PQSM ...