51
OPTIONAL IR MODULE
Hydrocarbons:
Range:
Overrange
Accuracy
Resolution
0-5,000ppm
10,000ppm
+5% of reading and + 12ppm vol.
1ppm
CO
2
:
Range:
Overrange
Accuracy
Resolution
0-20%
40%
+5% of reading and + 0.5% vol.
0.1%
CO:
Range:
Overrange
Accuracy
Resolution
0-10%
20%
+5% of reading and + 0.2% vol.
<30%
0.1%
Response time T90:
30 seconds
Warm up time:
3 minutes
Operating temperature range:
5 to 50 deg C.
Operating humidity:
10-80% non condensing
Power:
Supplied by KANE9206
Conversion Factors from a Hexane Calibration
Hexane
multiply by 1
Propane
multiply by 0.5
Methane
multiply by 0.05
HANDSET
Dimensions
240 mm long
135 mm high
70 mm wide
Keypad
tactile keys
Display
graphical with backlight and contrast control
ANALYSER
Dimensions
420 mm long
345 mm high
225 mm wide